98 lite blue Installation Manual
Card Thickness - 0.030 inches thick
ANSI/ISO Standards 7810, 7811 1/51 7812, and 7813
Card Reader - Proximity Reader
ANSI/BHMA A156.25 compliant
Compatible with HID proximity cards
Wiegand output
Card Read Range: up to 4 inches
Compliance to FCC Part 15, RSS-210 of Industry Canada
ESD Protection: 12KV
Card formats
-Can read all card formats up to 255 bits.
Request-to-exit
- The sensor/switch is built-in and will be triggered from the activation of the door lever on the
protected side of the door.
Request-to-enter
- The sensor/switch is built-in as a momentary switch on the lock.
Clutch Position
- Schlage AD-400 locks provide a way to lock or unlock a door and monitor access from a
remote location. Schlage AD-400 locks are fail-safe from the protected side of the door.
Operational environment
Temperature: -35°C to +66°C
Humidity: 20% RH to 95% RH (non-condensing)
Power source
The Schlage AD-400 lock uses 4 or 8 AA alkaline battery packs. Optionally can be powered by 12VDC or 24VDC.
Operating voltage
Power Requirements (Battery): 4 AA batteries that will supply 6.2 volts.
The locks will continue to operate down to 4.5 volts before reaching a Low Battery state.
At 4.0 volts the lock reaches a battery critical state and will shut down and go into a failsafe or fail lock
mode depending on what the operations in the SUS have been set to.
Power Requirements (wired): 12 to 24VDC
Current Requirements: Standby: 55 micro Amps typical (Proximity version)
Power consumption: 300mA max.
Battery Life - Up to 2 years with 4AA (8AA option available for extended battery life)
Range
- The Schlage AD-400 Lock can have a range up to 200 feet on one floor when used in normal office
interior construction and up to 1000 feet line of sight.
Transmitter Power - Up to 200 mW
Receiver Sensitivity - 90dBm typical
Wiegand technology to external reader