Functions On Mercury Controller - Vanderbilt lite blue Manual

Table of Contents

Advertisement

Chapter 1 lite blue
RESET / SHUTDOWN
Hold for 10 seconds for Power Down. Refer to LED Indicators.

Functions On Mercury Controller

J10
- micro SD connection for flash memory.
J12
- USB HOST (reserved for future use).
S1
- System Dip Switches
1 - Enable / Disable SSL encryption. ON enables. OFF disables. Default is ON.
2 - SSH Toggle. Default is ON. SSH session available for 10 minutes on System Restart and for 30
minutes after S1-SW2 position changed once disabled.
3 - Not Used.
4 - Not Used.
J5
- RS485 Termination (default = Off)
J9
- RS485 Termination (default = Off)
J7
- PASS 12V = Reader Power Select
12 V Available to Reader Ports (min 20 V in)
Input Power "Passed Through" to Reader Ports
Verify Manufacturer Specifications for Reader Head Voltage Maximum
VLBIM06/15/15 v4.1.0
- Hold for 5 - 9 seconds and release for Reboot.