Upgrading Software

Manually Unlock Doors for Upgrade

When finishing an upgrade of the lite blue software, the system will briefly lose communication, causing the doors
to lock. It is recommended that you use the Door Status and Control section of
commonly used doors before running the upgrade. The doors will stay in the unlock state until system
communication is restored, at which point they will revert to their normal function.

Disable Encryption

If upgrading to 2.0 or above it is necessary to turn off SSL encryption. See the lite blue Pin Functions section for
details on disabling SSL.

File Not Authorized Warning While Upgrading

Check the date that lite blue is set to. This error occurs if lite blue's date is out of synch with the current date. If
the date will not reset the battery needs to be changed. See the Battery Replacement section for details.

System Reboot

When the system is rebooted (as in the case of a power outage) it takes a little time for the personnel database to
reload. During the reloading process the doors of the system will function normally, however activity will not be
logged until the reloading process is finished. This means that the Activity Monitor and the Door Status and
Control sections will not show activity or status until the system has reloaded.

Discovery and Configuration Tool

If either lite blue or an VBB-NRI cannot be found by the Discovery and Configuration Tool:
Check to make sure any local Firewall software is turned off
Make sure they are on the same local network as the computer running the Discover and Configuration Tool

Errors When Logging In or Saving Records to the Database

If you receive an error message when logging in or when attempting to save data to the database:
lite blue
1
Hold the
Controller for at least 10 seconds.
2
After 10 seconds LED D7 will stay on sold and the
3
Remove power from MAIN POWER IN VBB and reconnect to power up
4
If operation is not restored contact Vanderbilt Technical Support.
RESET/SHUTDOWN Switch located behind the top left corner of the Mercury EP4502
lite blue
lite blue
will power down within 1 second.
lite blue
to manually unlock any
.