Replacing AirCoat flat jet tips

1. Switch off control unit.
2. Relieve spray gun and system
pressure!
3. Lock spray gun. Turn locking screw
clockwise until stop. (look in spray-
ing direction)
4. Unsrew cap ring (I) and remove air
cap (H).
5. Remove AirCoat tip insert (F) and
brush cleaning solvent until all tra-
ces of paint are dissolved.
Handle the hard metal tip insert (C) with care. Do not clean it with sharp metal ob-
jects.
6. Assembly: Fit tip insert (F) on paint channel (G).
7. Fit air cap (H) onto fan nozzle (F); make sure that the pins in the air cap fit into the
grooves in the tip.
8. Fit cap ring (I) with air cap (H) onto spray gun body (E).
9. Adjust desired jet level by means of air cap horns (X) and tighten cap ring (I) by
hand.
4.8

Cleaning of AirCoat flat jet tips

For disassembly and assembly see of AirCoat nozzles chapter 4.7.
The AirCoat nozzle (F) can be placed into a cleaning solvent which has been
recommended by the paint manufacturer. Do not treat the hard metal on the AirCoat
nozzle using sharp edged objects.
4.9

Clogging of AirCoat flat jet tips

For blockages in the AirCoat flat jet tip the accessory - tip cleaning device - is available
with the partnumber 0139 014.
This tip cleaning device can be used together with the GM 2000 EAC to flush out
blocked AirCoat flat jet tips in the opposite direction to the usual spray direction.