Operating manual Manual Powder System SPRINT XE
4   Basic Safety Instructions
4 on sharp edges
4 on moving parts
4 on hot surfaces
4 Ensure that the hoses are never run over by vehicles (e.g., fork lifts), or that the hoses
are never put under pressure from the outside in any other way.
4 Ensure that the hoses are never kinked. Observe maximum bending radii.
4 Ensure that no work is ever performed with a damaged hose.
4 Make sure that the hoses are never used to pull or move the device.
4.2.5   Electrical Connection Cables
Risk caused by improperly laid cables!
Risk of injury and damage to the device.
4 Properly lay connection cables and check them regularly.
4 Immediately replace damaged connection cables.
4 Ensure that no work is ever performed with a damaged connection cable.
4 Do not lay connection lines on travel paths of forklifts or through doors/gates.
4 Do not lay connection lines in the area of walkable hallways or paths to avoid the risk of
tripping.
4.2.6   Cleaning and Flushing
Danger due to cleaning and flushing!
Explosion hazard and damage to the device.
4 Before starting cleaning or any other manual work, the high voltage in the spray area
must be shut down and locked to prevent it from being switched back on.
4 Lock the compressed air supply and decompress the device.
4 Secure the device against being switched back on without authorization.
4 Use only electrically conducting and grounded tanks for cleaning fluids.
4 Preference should be given to non-ignitable cleaning fluids.
4 Ignitable cleaning liquids may only be used if all high-voltage parts are discharged to a
discharge energy of less than 0.24 mJ after shutting off the high voltage before these
parts can be reached. Most ignitable solvents have an ignition power in the range of
0.24 mJ, corresponding to 60 nC.
4 The flash point of the cleaning agents must be at least 15 K over the ambient
temperature.
4 Note the details provided by the powder lacquer manufacturer.
4 To correct for dust deposits, only mobile industrial vacuums of type 1 may be used (see
EN 60335-2).
4 Take measures for workplace safety (see Chapter "A Safe Work Environment").
4.2.7   Maintenance and Repair
Danger due to improper maintenance and repair!
Danger to life and equipment damage.
4 Only a WAGNER service center or a specially trained person may carry out repairs and
replace parts.
Order number 2354920 | Edition 01/2023