Flow Control - Allied Telesis AT-GS920/16 Installation And User Manual

Gigabit ethernet unmanaged switches
Table of Contents

Advertisement

GS920 Series Gigabit Ehternet Switch Installation and User's Guide

Flow Control

DIP switch # 5 enables or disables the Flow Control feature. See Figure
42, "Front Panel Configuration Switches and LEDs" on page 72 for the DIP
switch location on the front panel.
Note
Loop Detection must be disabled when the Flow Control feature is
enabled. See "Disabling Loop Prevention" on page 79
Enabling Flow Control
Perform the following procedure to enable the Flow Control feature:
1. Set DIP switch # 5 to the UP position to enable this feature. See
Figure 51.
Figure 51. DIP Switch Settings for Enabling Flow Control
2. Turn the power OFF by unplugging the AC power cord and then back
ON again by reconnecting it to the AC outlet on the switch. The new
switch setting is now implemented and effective and the Flow Control
feature is enabled.
Note
A recently changed DIP switch setting becomes effective ONLY
after you turn the switch's AC power OFF and then back ON.
82