Installation

3.5.6 Bleeding the hood lifting cylinder (option)

1.
2.
3.
4.
5.
WD-7 DUPLUS
Close the hood.
Loosen the hose connection of the first air cylinder approx. 2-3 turns using
a 13 mm box wrench.
Keep the hood in the closed position. Press the up button. Check that only
water and no air comes out of the hose connection. Otherwise repeat the
procedure.
Tighten the hose connection with the hose still in the lower position.
Repeat the same procedure with the second cylinder.
16