Table 9-8
Test Port Input (continued)
Description
Trace Noise
HP 8712ET/8712ES:
Narrowband:
Magnitude
Phase
Broadband:
Magnitude
HP 8714ET/8714ES:
Narrowband:
Magnitude
Phase
Broadband:
Magnitude
a. Trace noise is defined for a transmission measurement in CW mode, using a "through"
cable having 0 dB loss, with the source set to 0 dBm, and the analyzer's averaging func-
tion toggled off.
HP 8712ET/ES and HP 8714ET/ES Test Port Input
Spec.
Narrow
(250 Hz)
a
0.01 dB rms 0.03 dB-pp
0.01 dB rms 0.01 dB-pp
0.01 dB rms 0.02 dB-pp
0.01 dB rms
ES User's Guide
Typical
System Bandwidths:
Narrow
Med Wide
(250 Hz)
(4000 Hz)
0.12 dB-pp
0.2 Deg-pp
2.5 Deg-pp
0.02 dB-pp
0.06 dB-pp
0.2 Deg-pp
0.8 Deg-pp
0.01 dB-pp
0.03 dB-pp
Specifications
Wide
(6500 Hz)
0.28 dB-pp
3.4 Deg-pp
0.15 dB-pp
0.23 dB-pp
1.8 Deg-pp
0.16 dB-pp
9-35