Provisioning Station Clock Output - Alcatel-Lucent 1643 AMS User's Operation Manual

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams) release 1.0 through 7.2
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Timing provisioning

Provisioning station clock output

...................................................................................................................................................................................................................................
When to use
The purpose of this procedure is to specify the timing source to be used as a reference
for the station clock output signals.
The procedure must be executed when:
• A timing reference needs to be provided to external "in station" equipment.
• A regenerator loop is needed.
Related information
Related procedures are:
"Provisioning timing sources " (p. 7-19)
"Provisioning system timing" (p. 7-29)
"Provisioning output port timing" (p. 7-44)
Parameters used in this procedure can be found at
clock output" (p.
Before you begin
Before starting this procedure, make sure that:
• The "Provision Timing Sources" procedure is completed
• The network timing plan is available
Set priority and lock out
To set the priority or the lockout for a timing source follow this procedure:
...................................................................................................................................................................................................
Select Provisioning --> Timing --> Output Timing.
1
Result:
appears.
...................................................................................................................................................................................................
Select a source to edit from the list and click
2
Sources field
Result:
window appears.
...................................................................................................................................................................................................
Set Priority or Lock Out Request.
3
...................................................................................................................................................................................................................................
7-36
7-40).
The Provisioned NE Station Clock Output Timing Information window
.
The Edit Automatic Selection Criterions for NE STCLK Output Timing
Alcatel-Lucent - Proprietary
See notice on first page
"Parameters for provisioning station
Edit
in the Station Clock Output Timing
365-312-807R7.2
Issue 4, May 2007