Alarm management
Suppress
This button suppresses all active (current) alarms so that the next incoming alarm can
be seen on the unit LED by the maintenance personnel. When this button is pressed,
the alarm is said to "hide". Consequently, the next alarm is free to be lit on the system
controller user panel. The suppressed LED remains lit as long as any of the suppressed
alarms is active and not yet trouble-cleared. It is possible to suppress any current alarm
on another network element during a remote session.
Suppressed alarms
This field indicates whether some of the listed alarms are suppressed or not. This field
will be autonomously updated each time an alarm changes status to "Clear".
Time raised
The time at which the alarm was raised. The default format is
MM/DD/YYYY:00(hr):00(mn):00(s) but can be modified. The displayed time should
be the local ITM CIT time, that is the local time zone.
Time cleared
The time at which the alarm was cleared and moved to the History Alarm list. The
default format is MM/DD/YYYY:00(hs):00(ms):00(s) but can be modified. The
displayed time should be the local ITM CIT time, that is the local time zone.
<—
Removes a specific setting entry from the configured specific settings. The button is
enabled only if one alarm type has been selected for which specific settings exist.
—>
Copies the selected global settings entry onto the specific settings.
....................................................................................................................................................................................................................................
365-312-807R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
Parameters for identifying the alarms
6-27