Index
Single-pair High-speed DSL
SHDSL,
8-30
Slot, 8-186, 8-186, 10-46,
10-53
Provisioning,
5-20
Slot Select field,
6-26
SNC protection, 8-152, 8-184,
9-24
edit,
8-188
switch,
9-25
view,
8-185
SNC/N,
8-18
Software
view,
12-6
Software Release Description,
xxviii
Software upgrade,
12-11
Source, 6-71,
6-77
Source field,
6-26
Source selection,
7-42
Spanning tree,
8-65
Spanning tree protocol,
Spanning tree with VPN
registration protocol (STVRP),
8-49, 8-60,
8-69
specific alarm,
6-23
Specific reported,
6-26
Specific severity,
6-26
SRD,
xxviii
SSM out,
7-48
SSU,
7-7
SSU-L, 7-7,
7-9
SSU-T, 7-7,
7-9
Standards Compliance,
Static VLAN ID list,
Station clock,
7-36
Station clock output, 7-40,
Status, 6-71,
6-77
...................................................................................................................................................................................................................................
365-312-807R7.2
Issue 4, May 2007
Status field,
STCLK output,
Stop time,
STP,
See: Spanning tree protocol
bridge priority,
root bridge address,
root bridge priority,
root cost, 8-118,
Strict policing mode,
Strict priority,
STVRP, 8-49, 8-69,
See: Spanning tree with
Subscribe,
Subscribe all,
Supervision
concepts,
Supervision list
parameters,
view,
8-45
Suppress,
Suppress Dependency on
Station Alarms,
Suppressed Alarms,
Switch
request, 7-27, 7-34,
status, 7-27, 7-34,
Switch mode, 8-200, 9-26,
Switch priority,
Switch request, 9-26,
Switch state, 8-192,
Synchronization supply unit
1-16
See: SSU
8-69
-local
-transit
7-42
System QL,
Alcatel-Lucent - Proprietary
6-26
7-42
10-53
8-118
8-118
8-118
8-118
8-119
8-87
8-91
8-79
VPN registration protocol
6-72
6-72
6-13
6-69
6-63
6-26
6-30
6-27
7-42
7-42
8-46
9-29
9-29
See: SSU-L
See: SSU-T
7-34
See notice on first page
System timing, 7-29,
............................................................
Tagging mode, 8-114,
T
TAP properties
edit,
4-62
Templates,
Termination point,
Termination Point,
Termination point,
See: TP
Termination points, 8-151,
8-159,
10-9
provision,
Test loop,
Threshold
select,
Threshold Crossing Alert,
Threshold values
change,
Thresholding, 10-45,
thresholds,
Thresholds,
thresholds,
Thresholds
Alarms,
enable,
TI mode,
9-17
TIM,
9-7
9-29
TIM detection,
Time,
6-72
Time cleared, 6-27,
Time raised, 6-27,
Timing,
7-35
alarm reporting,
Loop,
7-13
Mode,
mode, 7-35,
7-32
8-119
5-5
9-7
10-45
10-54
9-10
9-5
9-20
10-8
9-22
10-54
10-8
10-29
10-30
10-27
10-41
9-18
6-78
6-78
7-48
7-5
7-48
IN-7