Alarm management

Alarm supervision concepts

...................................................................................................................................................................................................................................
Generalities
Alarm supervision is a feature that allows maintenance personnel to monitor currently
raised alarms on a local network element, or on several other network elements
belonging to the same subnetwork. In order to view the remote network element
current alarms list, it is required to have subscribed it to the supervision list.
Subscribing a network element to a supervision list means that the local network
element (to which the ITM CIT is connected) is granted access permission to a remote
network element, with a specific NSAP address. The access rights is one of "view
only". The list of all subscribed network elements is kept in a register on the network
element. This list is called the Supervision Log file. It's path and name can be
configured on the ITM CIT. This list modified, reset to default, saved and loaded at a
later time from another network element. The details from this list can be viewed on
the Supervision List window, on the ITM CIT.
Below is a description of each important windows related to alarm supervision
Supervision window
Alarm Supervision
Alarm Subscription
Supervision: Current Alarm
Supervision: Add network
Element
Supervision: Edit network
element Information
Subscription/Unsubscribing
Progress Display
...................................................................................................................................................................................................................................
365-312-807R7.2
Issue 4, May 2007
Information
Lists all the network element elements (subscribed
and unsubscribed) and displays the current alarm
types (red circles). Detailed information can be
seen in the Supervision: Current Alarmwindow. The
network element MUST be subscribed in order to
see the raised alarms types.
Allows to modify the subscription state of a
network elements appearing in the Alarm
Supervision window.
Gives detailed information about all currently
raised alarm types for a subscribed network
element appearing on the Alarm Supervision
window.
Allows to add a network element on the Alarm
Supervision window.
Allows to modify information about a network
element that appears on the Alarm Supervision
window.
Displays the % completion during the subscription
or unsubscription process.