Equipment provisioning
Centralized MDI signaling
...................................................................................................................................................................................................................................
Introduction
In this mode, the NE will drive its MDOs according to MDI information it has
centralized from local and remote NEs. A CIT locally connected is used to subscribe or
unsubscribe to MDI status report from remote NEs. However, the NE will be able to
drive its MDO whether a CIT is locally connected or not.
The MDOs behavior in this mode:
• MDO-2 is active when one or more centralized MDI alarms with severity
PROMPT are raised
• MDO-3 is active when one or more centralized MDI alarms with severity
DEFERRED are raised
• MDO-4 is active when one or more centralized MDI alarms with severity INFO are
raised.
Example
This mode is fine for the following application:
...................................................................................................................................................................................................................................