1.1 System Overview

The Honeywell Analytics Ver tex M™ System
continuously monitors up to 24 remote locations
for toxic gases. It responds to gases that exceed
programmed levels by:
Triggering alarms and opening event windows
to warn operators of high or low concentrations
Triggering relays to external devices
Displaying the location, gas type and gas
concentration
Storing the alarm information in a database
The Vertex M System provides fast response to a wide
range of gases. Each location may be up to 400 ft
(122 m) from the Vertex M System. The system uses
one or more of Honeywell Analytics' Chemcassette
analyzers, with or without pyrolyzer, to provide a
monitoring system tailored to meet the requirements
of the facility.
The Vertex M System incorporates a range of redundant
and protective features for maximum uptime:
Intelligent analyzer modules allow one to stop
monitoring with no effect on the remaining
modules
Power supplies are redundant
Pumps are redundant
The system powers up in the same state as
when powered down
Section 1 - Introduction
Filters, Chemcassettes
components in one of the analyzers can
be replaced while the remaining analyzers
continue to function
Operation can be through an LCD touch screen or
through a local area network (LAN).
Chemcassette
is a registered trademark of Honeywell Analytics, Inc.
®

1.1.1 Manufacturer

The Vertex M System is manufactured by:
Honeywell Analytics Inc.
405 Barclay Boulevard
Lincolnshire, IL 60069 USA
www.honeywellanalytics.com

1.1.2 General Safety

®
Follow all installation and operational instructions to
ensure the safe and reliable operation of this unit.
If this monitor is used in a manner not specified by
Honeywell Analytics Inc., the protection provided by
the equipment may be impaired.

1.2 System Components

The following photos illustrate Vertex M System
components, ports, connections and controls. From
the main front and back photos, click on the labels to
see the detail photos.
1-2
and major
®