Show Nlm Oper-Status; Show Snmp Notify-Filter; Additional Trap Commands; Memory - Edge-Core ECS2100-10T Reference Manual

10/28-port web-smart pro gigabit ethernet switch
Hide thumbs Also See for ECS2100-10T:
Table of Contents

Advertisement

Chapter 5
| SNMP Commands

Additional Trap Commands

show nlm oper-status

show snmp
notify-filter
Additional Trap Commands

memory

This command shows the operational status of configured notification logs.
Command Mode
Privileged Exec
Example
Console#show nlm oper-status
Filter Name: A1
Oper-Status: Operational
Console#
This command displays the configured notification logs.
Command Mode
Privileged Exec
Example
This example displays the configured notification logs and associated target hosts.
Console#show snmp notify-filter
Filter profile name
----------------------------
A1
Console#
This command sets an SNMP trap based on configured thresholds for memory
utilization. Use the no form to restore the default setting.
Syntax
memory {rising rising-threshold | falling falling-threshold}
no memory {rising | falling}
rising-threshold - Rising threshold for memory utilization alarm expressed in
percentage. (Range: 1-100)
falling-threshold - Falling threshold for memory utilization alarm expressed
in percentage. (Range: 1-100)
Default Setting
Rising Threshold: 90%
Falling Threshold: 70%
Command Mode
Global Configuration
IP address
----------------
10.1.19.23
– 180 –