Edge-Core ECS2100-10T Reference Manual page 269

10/28-port web-smart pro gigabit ethernet switch
Hide thumbs Also See for ECS2100-10T:
Table of Contents

Advertisement

Example
The following example enables the dynamic QoS feature on port 1.
Console(config)#interface ethernet 1/1
Console(config-if)#network-access dynamic-qos
Console(config-if)#
network-access
Use this command to enable dynamic VLAN assignment for an authenticated port.
Use the no form to disable dynamic VLAN assignment.
dynamic-vlan
Syntax
Default Setting
Enabled
Command Mode
Interface Configuration
Command Usage
Example
The following example enables dynamic VLAN assignment on port 1.
Console(config)#interface ethernet 1/1
Console(config-if)#network-access dynamic-vlan
Console(config-if)#
[no] network-access dynamic-vlan
When enabled, the VLAN identifiers returned by the RADIUS server through the
802.1X authentication process will be applied to the port, providing the VLANs
have already been created on the switch.
The VLAN settings specified by the first authenticated MAC address are
implemented for a port. Other authenticated MAC addresses on the port must
have same VLAN configuration, or they are treated as an authentication failure.
If dynamic VLAN assignment is enabled on a port and the RADIUS server
returns no VLAN configuration, the authentication is still treated as a success,
and the host assigned to the default untagged VLAN.
When the dynamic VLAN assignment status is changed on a port, all
authenticated addresses are cleared from the secure MAC address table.
– 269 –
Chapter 9
| General Security Measures
Network Access (MAC Address Authentication)

Hide quick links: