Setting The Inductive Proximity Switches (Option); Opening The Housing Of The Top Control Continuous; Positioning The Inductive Proximity Switches - Burkert 8630 Operating Instructions Manual

Top control continuous
Hide thumbs Also See for 8630:
Table of Contents

Advertisement

I
NSTALLATION

* Setting the inductive proximity switches (Option)

ATTENTION!
In order to set the inductive proximity switches, the housing of the TOP Control
Continuous must opened. Switch off the operating voltage before making this
intervention!

Opening the housing of the TOP Control Continuous

➔ Remove any lead seals or fastenings present between cover and housing.
➔ Turn the cover anticlockwise and lift it off.

Positioning the inductive proximity switches

➔ The inductive proximity switches are positioned vertically with one adjusting screw each:
Turning clockwise
causes upward adjustment
ATTENTION!
On adjusting the height of the inductive proximity switches, make sure that adjacent
flexes are not pulled (e.g. by getting hooked in the proximity switches). If this is not
adhered to, plugged connections may be damaged or loosened).
50 - 8630
Screw to adjust the lower proximity switch
Screw to adjust the upper proximity switch
Turning anticlockwise
causes downward adjustment