Dancer Roll Setting - Mitsubishi Electric A800 Plus Series Function Manual

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

3.5.6

Dancer roll setting

Set the target position for the dancer roll control.
Select the input method to the inverter (analog input terminal) for dancer signal input.
Pr.
Name
133
R101
PID action set point
(A611)
363
Dancer / tension sensor
R102
feedback input selection
Dancer / tension sensor
1227
feedback input filter time
R103
constant
Block diagram
3
Terminal 2
4
Terminal 4
Pr.363
5
Terminal 1
6
Terminal 6
PID set point (Pr.133)
• Set the target position (neutral position) of the dancer roll in Pr.133 PID action set point.
Pr.133 setting
600%
+100%
500% (initial setting)
0%
400%
-100%
• If the position signal input from the dancer roll through terminal 1 is 10 V at the upper limit position, -10 V at the lower limit
position, and 0 V at the neutral position (target position), set 500% in Pr.133. If the signal is -5 V at the neutral position
(target position), set 450% in Pr.133. A voltage from -10 V to 10 V can be input through terminal 1.
Dancer signal input through terminal 1, terminal 6
Dancer roll position signal
(Pr.133 (dancer roll center))
10 V (600%)
5 V (550%)
Dancer roll
lower limit position
NOTE
• Set "86" in Pr.52 to monitor the dancer roll position in %. When the negative indication is invalid, the monitored value is
indicated as an offset from 1000%.
Initial value
500%
9999
0
Primary
delay filter Clamping
100%
Dancer roll position
-100%
Pr.1227
Actual set point
0 (500%)
Dancer roll
upper limit position
-5 V (450%)
-10 V (400%)
Dancer feedback speed control details
Setting
range
400 to 600%
Set the set point for the dancer roll control.
3
The measured value is input through terminal 2.
4
The measured value is input through terminal 4.
5
The measured value is input through terminal 1.
The measured value is input through terminal 6 (FR-
6
A8AZ).
9999
No function
0
Without filter
Set the primary delay filter for the dancer signal input
0.01 to 5 s
value.
Dancer signal input through terminal 2, terminal 4
Dancer roll position signal
(Pr.133 (dancer roll center))
10 V/20 mA (600%)
7.5 V/16 mA (550%)
Dancer roll
lower limit position
5 V/12 mA (500%)
2.5 V/8 mA (450%)
0 V/4 mA (400%)
DANCER FEEDBACK SPEED CONTROL
Description
Dancer roll
upper limit position
3
71

Advertisement