Mitsubishi Electric A800 Plus Series Function Manual page 88

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Pr.
Name
472
Second PID differential time
R121
for values below set point
473
Third PID proportional band
R122
474
Third PID integral time
R123
475
Third PID differential time
R124
476
Third PID proportional band
R125
for values below set point
477
Third PID integral time for
R126
values below set point
478
Third PID differential time for
R127
values below set point
479
Fourth PID proportional band
R128
480
Fourth PID integral time
R129
481
Fourth PID differential time
R130
482
Fourth PID proportional band
R131
for values below set point
483
Fourth PID integral time for
R132
values below set point
484
Fourth PID differential time
R133
for values below set point
486
Deviation A
R140
487
Deviation B
R141
488
Deviation C1
R142
489
Deviation C2
R143
490
PID gain A
R144
491
PID gain B
R145
492
PID gain C1
R146
493
PID gain C2
R147
494
PID gain D
R148
Setting
Initial value
range
0.01 to 10 s
9999
9999
0.1 to 1000%
9999
9999
0.1 to 3600 s
9999
9999
0.01 to 10 s
9999
9999
0.1 to 1000%
9999
9999
0.1 to 3600 s
9999
9999
0.01 to 10 s
9999
9999
0.1 to 1000%
9999
9999
0.1 to 3600 s
9999
9999
0.01 to 10 s
9999
9999
0.1 to 1000%
9999
9999
0.1 to 3600 s
9999
9999
0.01 to 10 s
9999
9999
600%
400.1 to 600%
400%
400 to 599.9%
400.1 to
599.9%
9999
9999
400.1 to
599.9%
9999
9999
0.1 to 1000%
9999
9999
0.1 to 1000%
9999
9999
0.1 to 1000%
9999
9999
0.1 to 1000%
9999
9999
0.1 to 1000%
9999
9999
DANCER FEEDBACK SPEED CONTROL
Dancer feedback speed control details
Description
Set the second PID differential time for values below set
point.
As set in Pr.469.
Set the third PID proportional band.
As set in Pr.129/Pr.464.
Set the third PID integral time.
As set in Pr.130/Pr.465.
Set the third PID differential time.
As set in Pr.134/Pr.466.
Set the third PID proportional band for values below set
point.
As set in Pr.473.
Set the third PID integral time for values below set
point.
As set in Pr.474.
Set the third PID differential time for values below set
point.
As set in Pr.475.
Set the fourth PID proportional band.
As set in Pr.129/Pr.464.
Set the fourth PID integral time.
As set in Pr.130/Pr.465.
Set the fourth PID differential time.
As set in Pr.134/Pr.466.
Set the fourth PID proportional band for values below
set point.
As set in Pr.479.
Set the fourth PID integral time for values below set
point.
As set in Pr.480.
Set the fourth PID differential time for values below set
point.
As set in Pr.481.
Set the deviation used for selecting PID gain A.
Set the deviation used for selecting PID gain B.
Set the deviation used for selecting PID gain C1.
The PID gain is 100%.
Set the deviation used for selecting PID gain C2.
The PID gain is 100%.
Set the gain for the deviation A.
The PID gain is 100%.
Set the gain for the deviation B.
The PID gain is 100%.
Set the gain for the deviation C1.
The PID gain is 100%.
Set the gain for the deviation C2.
The PID gain is 100%.
Set the gain for the deviation in the C1 to C2 range.
The PID gain is 100%.
3
87

Advertisement

Table of Contents
loading

Table of Contents