Mitsubishi Electric A800 Plus Series Function Manual page 70

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

3.5.5
Acceleration/deceleration time setting for line
speed command
Set the acceleration/deceleration time for the line speed command.
Pr.
Name
394
First acceleration time for
R251
line speed command
395
First deceleration time for
R252
line speed command
100
Second acceleration time
R253
for line speed command
101
Second deceleration time
R254
for line speed command
102
Third acceleration time for
R255
line speed command
103
Third deceleration time for
R256
line speed command
Line speed command
393
acceleration/deceleration
R250
reference
621
Allowable deviation from
R423
target line speed
∗1
The increment varies depending on the Pr.358 setting.
Block diagram
Line speed
command
Acceleration/deceleration time setting (Pr.100 to Pr.103, Pr.393 to Pr.395,
X105 signal, X106 signal)
• Settings of acceleration/deceleration time for line speed command are used in the command for accelerating/decelerating
the line speed.
• Use Pr.393 Line speed command acceleration/deceleration reference for setting time in each parameter.
• Use Pr.21 Acceleration/deceleration time increments to set the minimum increment of the acceleration/deceleration
time.
Pr.21 setting
Minimum increment
0
0.1 s
1
0.01 s
Initial value
Setting range
15 s
0 to 3600 s
15 s
0 to 3600 s
15 s
0 to 3600 s
15 s
0 to 3600 s
15 s
0 to 3600 s
15 s
0 to 3600 s
1000 m/min
1 to 6553.4 m/min
∗1
0 m/min
0 to 6553.4 m/min
∗1
X105-OFF
Pr.394
Pr.395
X105-ON
Pr.100
Pr.101
Pr.102
Pr.103
Dancer feedback speed control details
Set the acceleration time (from a stop to Pr.393) for
the line speed command.
Set the deceleration time (from Pr.393 to a stop) for
the line speed command.
Set the second acceleration time for the line speed
command.
Set the second deceleration time for the line speed
command.
Set the third acceleration time for the line speed
command.
Set the third deceleration time for the line speed
command.
Set the reference line speed for the acceleration/
∗1
deceleration time for the line speed.
The Y237/Y238 signal output range can be set for the
∗1
target line speed command.
X106-OFF
Unit switchover
Pr.21
X106-ON
DANCER FEEDBACK SPEED CONTROL
Description
Line speed command
value in consideration of
acceleration/deceleration
69