Parameters (functions) and instruction codes under different control methods
Pr.
Name
Initial winding diameter calculation
1254
deadband 2
1255
Accumulated amount
1256
Speed control P gain at start
1257
Speed control integral time at start
1258
Integral term limit at start
1259
PID term limit at start
1262
Winding length increment
1263
Stored winding length (lower 4 digits) 3F
Winding length detection (lower 4
1264
digits)
1265
Line multi-speed setting (high-speed) 41
Line multi-speed setting (middle-
1266
speed)
1267
Line multi-speed setting (low-speed)
1268
Line multi-speed setting (speed 4)
1269
Line multi-speed setting (speed 5)
1270
Line multi-speed setting (speed 6)
1271
Line multi-speed setting (speed 7)
1272
Line multi-speed setting (speed 8)
1273
Line multi-speed setting (speed 9)
1274
Line multi-speed setting (speed 10)
1275
Line multi-speed setting (speed 11)
1276
Line multi-speed setting (speed 12)
1277
Line multi-speed setting (speed 13)
1278
Line multi-speed setting (speed 14)
1279
Line multi-speed setting (speed 15)
Winding diameter monitoring
1280
reference
Commanded tension monitoring
1281
reference
1282
Tension command cushion time
1283
Cushion time reference tension
1284
Taper mode selection
1285
Taper setting analog input selection
1286
Winding diameter at taper start
1287
Taper ratio setting
1288
Data table winding diameter 1
1289
Data table taper ratio 1
1290
Data table winding diameter 2
1291
Data table taper ratio 2
1292
Data table winding diameter 3
1293
Data table taper ratio 3
1294
Data table winding diameter 4
1295
Data table taper ratio 4
1296
Data table winding diameter 5
1297
Data table taper ratio 5
1298
Stored winding length (upper 4 digits) 62
1299
Stored winding length increment
Winding length detection (upper 4
1346
digits)
1348
P/PI control switchover frequency
1349
Emergency stop operation selection
1401
Tension command increment
1402
Tension command input voltage bias
236
APPENDIX
Instruction
Control method
code
∗1
36
B6
C
37
B7
C
38
B8
C
39
B9
C
3A
BA
C
3B
BB
C
3E
BE
C
BF
C
40
C0
C
C1
C
42
C2
C
43
C3
C
44
C4
C
45
C5
C
46
C6
C
47
C7
C
48
C8
C
49
C9
C
4A
CA
C
4B
CB
C
4C
CC
C
4D
CD
C
4E
CE
C
4F
CF
C
50
D0
C
×
×
51
D1
C
×
×
52
D2
C
53
D3
C
×
×
54
D4
C
55
D5
C
56
D6
C
57
D7
C
58
D8
C
59
D9
C
5A
DA
C
5B
DB
C
5C
DC
C
5D
DD
C
5E
DE
C
5F
DF
C
60
E0
C
61
E1
C
E2
C
63
E3
C
2E
AE
D
×
×
30
B0
D
31
B1
D
01
81
E
×
×
02
82
E
×
×
∗2
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Parameter

Advertisement

Table of Contents
loading

Table of Contents