Parameter list (by parameter number)
Pr.
Pr.
group
Mechanical loss setting
1428
R559
frequency 5
1429
R560
Mechanical loss 5
Load characteristics
1480
H520
measurement mode
Load characteristics load
1481
H521
reference 1
Load characteristics load
1482
H522
reference 2
Load characteristics load
1483
H523
reference 3
Load characteristics load
1484
H524
reference 4
Load characteristics load
1485
H525
reference 5
Load characteristics maximum
1486
H526
frequency
Load characteristics minimum
1487
H527
frequency
Upper limit warning detection
1488
H531
width
Lower limit warning detection
1489
H532
width
1490
H533
Upper limit fault detection width
1491
H534
Lower limit fault detection width
Load status detection signal
1492
H535
delay time / load reference
measurement waiting time
1499
E415
Parameter for manufacturer setting. Do not set.
Pr.CLR
Parameter clear
ALL.CL
All parameter clear
Err.CL
Fault history clear
Pr.CPY
Parameter copy
Pr.CHG
Initial value change list
AUTO
Automatic parameter setting
Pr.Md
Group parameter setting
∗1
Differs according to the capacity.
• 6%: FR-A820-00046(0.4K), 00077(0.75K), FR-A840-00023(0.4K), 00038(0.75K)
• 4%: FR-A820-00105(1.5K) to 00250(3.7K), FR-A840-00052(1.5K) to 00126(3.7K)
• 3%: FR-A820-00340(5.5K), 00490(7.5K), FR-A840-00170(5.5K), 00250(7.5K)
• 2%: FR-A820-00630(11K) to 03160(55K), FR-A840-00310(11K) to 01800(55K)
• 1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K) or higher
∗2
The setting range or initial value for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
∗3
The setting range or initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
∗4
The initial value for the FR-A820-00490(7.5K) or lower and FR-A840-00250(7.5K) or lower.
∗5
The initial value for the FR-A820-00630(11K) or higher and FR-A840-00310(11K) and higher.
∗6
Differs according to the capacity.
• 4%: FR-A820-00490(7.5K) or lower, FR-A840-00250(7.5K) or lower
• 2%: FR-A820-00630(11K) to 03160(55K), FR-A840-00310(11K) to 01800(55K)
• 1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K)or higher
∗7
The value for the 200 V class.
∗8
The value for the 400 V class.
∗9
The setting is available only when a plug-in option that supports Vector control is installed. For details of the Vector control compatible options
supporting the parameter, refer to the Instruction Manual (Detailed) of the FR-A800 inverter or the Instruction Manual of the Vector control
compatible option.
∗10 The parameter number in parentheses is that used (displayed) on the LCD operation panel and the parameter unit.
∗11 The increment varies depending on the Pr.358 setting.
∗12 The increment varies depending on the Pr.1262 setting.
∗13 The setting varies with the Pr.1401 setting.
∗14 The initial value is for standard models.
∗15 The initial value is for separated converter types.
∗16 The setting is available only when the FR-A8AZ is installed.
∗17 For the details, refer to the Instruction Manual (Detailed) of the FR-A800 inverter in the enclosed CD-ROM.
∗18 For the details, refer to the Instruction Manual of the FR-A8AL.
30
PARAMETER LIST
Name
Setting range
0 to 400 Hz, 9999
900 to 1100%
0, 1 (2 to 5, 81 to 85)
0 to 400%, 8888, 9999
0 to 400%, 8888, 9999
0 to 400%, 8888, 9999
0 to 400%, 8888, 9999
0 to 400%, 8888, 9999
0 to 590 Hz
0 to 590 Hz
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 60 s
(0, )1
(0, )1
(0, )1
(0, )1 to 3
(0, )1, 2
Minimum
Initial value
setting
FM
CA
increments
0.01 Hz
9999
0.1%
1000%
1
0
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
0.01 Hz
60 Hz
50 Hz
0.01 Hz
6 Hz
0.1%
20%
0.1%
20%
0.1%
9999
0.1%
9999
0.1s
1s
1
0
1
0
1
0
1
0
1
0
Refer
Customer
to
setting
page
135
135
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17