Mitsubishi Electric A800 Plus Series Function Manual page 197

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Differences in the functions from the standard inverter
Function
Brake sequence control
Electronic bypass sequence
Stop frequency function
Stop-on-contact control
Load torque high-speed
frequency control
Anti-sway control function
Traverse function
Strengthened excitation
deceleration
Self power management
SSCNET III communication
(FR-A8NS)
FL remote communication
(FR-A8NF)
L
W
communication
ON
ORKSR
(FR-A8NL)
Torque control by variable-
current limiter control
Second motor control method
selection
4 mA input check
Stop mode at communication
error
Online auto tuning
DC injection brake (zero speed
control and servo lock)
JOG signal
Start count monitor
Changeover between inverter
and high power factor converter
Parameter information (when
the FR-LU08 is installed)
∗1
The Pr.178 to Pr.189 (input terminal function selection) setting is shown in the parentheses.
∗2
The Pr.190 to Pr.196 (output terminal function selection) setting is shown in the parentheses.
∗3
The monitor selection parameter setting is shown in the parentheses.
• The parameters related to cumulative pulse in the FR-A800-R2R are as follows, different from those in the FR-A800
standard inverters. The function of the parameters are the same as those of the FR-A800 standard inverters. (For details,
refer to the Instruction Manual (Detailed) of the FR-A800 inverter.)
Parameter name
Cumulative pulse clear signal selection
Cumulative pulse division scaling factor
Control terminal option-Cumulative pulse
division scaling factor
Cumulative pulse storage
NOTE
• Functions not mentioned above are the same as those of the FR-A800 standard inverter. (The functions added in and after
December 2017 are not supported.)
• For the details of general specifications, refer to the catalog or Instruction Manual of the FR-A800 inverter.
196
APPENDIX
Parameter
Pr.278 to Pr.284, Pr.639 to Pr.648,
Pr.650, Pr.651
Pr.135 to Pr.139, Pr.159
Pr.522
Pr.270, Pr.275, Pr.276
Pr.271 to Pr.274
Pr.1072 to Pr.1079
Pr.592 to Pr.597
Pr.660 to Pr.662
Pr.248, Pr.254
Pr.379, Pr.449, Pr.499
Pr.387 to Pr.392
Pr.451 setting range change
("6 and 106" are deleted.)
Pr.800 setting range change
("6 and 106" are deleted.)
Pr.451 setting range change
("0 to 2 and 100 to 102" are deleted.)
Pr.573 setting range change
("4" is deleted.)
Pr.777 is deleted.
Pr.502 setting range change
("3 and 4" are deleted.)
Pr.779 is deleted.
Pr.574 setting range change
("2" is deleted.)
Pr.1299
Pr.338 (The JOG signal can be sent
through communication.)
Pr.1410, Pr.1411
Pr.328
FR-A800 standard inverter
Pr.635
Pr.636
Pr.637
Pr.638
Input
Output
signal
signal
∗1
∗2
BRI (15)
BOF (20)
BRI2 (45)
BOF2 (22)
MC1 (17)
X95 (95)
MC2 (18)
X96 (96)
MC3 (19)
X19 (19)
X37 (37)
X94 (94)
X85 (85)
X88 (88)
X89 (89)
JOGF (57)
JOGR (58)
FR-A800-R2R series inverter
Pr.755
Pr.756
Pr.757
Pr.758
Monitor
∗3
SSCNET III communication