Pr.
Parameter name
Line speed at winding diameter
1246
∗1
calculated value activation
Winding diameter change
1247
∗1
increment amount limit
Number of averaging for
1249
∗1
winding diameter calculation
Winding diameter
1251
compensation speed filter time
∗1
constant
1252
Dancer lower limit position
∗1
Initial winding diameter
1253
∗1
calculation deadband
Initial winding diameter
1254
∗1
calculation deadband 2
1255
Accumulated amount
∗1
1258
Integral term limit at start
∗1
1259
PID term limit at start
∗1
Taper setting analog input
1285
selection
1286
Winding diameter at taper start
1287
Taper ratio setting
∗1
Adjustment parameter for adjusting the setting of another parameter.
∗2
The parameter number in parentheses is the one for use with the LCD operation panel and the parameter unit.
Initial
Setting
value
value
1 m/min
1 m/min
Setting Pr.1247 = "9999 (initial value)" disables the roll diameter
calculation.
9999
0.2 mm
Be sure to change the setting from the initial value for the roll
diameter calculation.
Use this parameter to enable the primary delay filter relative to
4
4
the result of the roll diameter calculation.
0 s
0.1 s
400%
500%
1.0%
10%
Use this parameter to prevent the dancer roll from moving too
9999
0%
much when the normal operation starts after the initial roll
diameter calculation is completed.
The setting value can be calculated from the setting of Pr.1253
Initial winding diameter calculation deadband
9999
270 mm
accumulated amount (300 mm) as follows: 300 mm × 0.9 = 270
mm
2.5%
1.5%
Use these parameters to adjust winding speed for the initial roll
diameter calculation.
2.5%
1.5%
9999
4
4: The taper ratio is input through terminal 4.
9999
800 mm
0%
9999
9999: The taper ratio is set through the analog input terminal.
Application examples
Remarks