Tension sensorless torque control details
Tension command through the CC-Link / CC-Link IE Field Network /
PROFIBUS-DP (Pr.804 = "1, 3, 5, 6")
• Set the tension command via the CC-Link communication (FR-A8NC), CC-Link IE Field Network communication (FR-
A8NCE), or PROFIBUS-DP communication (FR-A8NP).
• Set the tension command the same way as the torque command. (Refer to the Instruction Manual of each option for
details.)
Pr.804
setting
CC-Link
Tension command by
1, 6
Pr.365, Pr.366
∗1
Tension command by
3, 5
remote register (RWw1
or RWw2)
∗2
∗1
Can also be set from operation panel or parameter unit.
∗2
The tension command can also be performed by setting a value in Pr.365 or Pr.366.
∗3
The setting varies with the Pr.1401 setting.
∗4
When Pr.1401 = "0", enter the setting value multiplied by 100. When Pr.1401 = "1", enter the setting value multiplied by 10. For example, enter
10000 to set 100.00N when "0" is set in Pr.1401.
NOTE
• For the details of FR-A8NC, FR-A8NCE, FR-A8NP setting, refer to the Instruction Manual for the respective communication
options.
• For the details of the setting using the PLC function, refer to the PLC Function Programming Manual.
Tension command by 16-bit digital input (Pr.804 = "4")
• Execute tension command by 12-bit or 16-bit digital input using FR-A8AX (plug-in option).
• When a value other than "0" is set in Pr.1403 or Pr.1405, use Pr.1403 or Pr.1405 to calibrate the tension command value
input to the FR-A8AX.
• When "0" is set in both Pr.1403 and Pr.1405, the digital value input to the FR-A8AX is used as it is as the tension command
value.
• Use Pr.1401 to set the maximum tension command value.
NOTE
• For the details of the FR-A8AX setting, refer to the Instruction Manual of the FR-A8AX.
120
TENSION SENSORLESS TORQUE CONTROL
Tension command input
CC-Link IE
Tension command by
remote register
(RWw2)
∗2
Tension command value
Pr.1405
H7FFF
(H7FF)
Most significant bit = 1
Tension command value
10000
H7FFF
H7FF
(16 bits)
(12 bits)
Most significant bit = 1
PROFIBUS-DP
Tension command by Pr.365,
Pr.366
∗1
Tension command by the buffer
memory of PROFIBUS-DP (REF1
to 7)
∗2
Initial value
Digital input signal
H7FFF
0
Pr.1403
(H7FF)
Most significant bit = 0
2047
0
H7FF
H2710
(12 bits)
Most significant bit = 0
Setting range
0 to 100 N
∗3∗4
H7FFF
Digital input signal
(16 bits)
Setting
increments
0.01 N
∗3