8.2.5
Line speed at winding diameter calculated value
activation
Set the line speed command value or actual line speed to start winding diameter calculation. When the line speed command
value or actual line speed is lower than the speed to start winding diameter calculation, winding diameter calculation is not
performed and the last winding diameter value is kept.
Pr.
Name
Line speed at winding
1246
diameter calculated value
R040
activation
∗1
The increment varies depending on the Pr.358 setting.
Line speed at winding diameter calculated value activation during
dancer feedback / tension sensor feedback speed control
• During dancer feedback speed control or tension sensor feedback speed control, when the line speed command value is
equal to or higher than Pr.1246, winding diameter calculation is performed, and the winding diameter calculation result is
updated. When the line speed command value is lower than the Pr.1246 setting, winding diameter calculation is not
performed and the last winding diameter value is kept.
• It is possible to prevent the change in the winding diameter, which may be caused by calculation errors at low-speed
operation.
Line speed command (m/min)
Pr.1246
Line speed
command value
Winding diameter
Initial
Setting range
value
1 m/min
0 to 6553.4 m/min
∗1
Winding diameter
value held
calculation in progress
value being updated)
WINDING DIAMETER COMPENSATION FUNCTION
Winding diameter calculation setting
Set the line speed command value or actual line speed
∗1
to start winding diameter calculation.
Winding diameter
Winding diameter
value held
(winding diameter
Description
Time
167
8

Advertisement

Table of Contents
loading

Table of Contents