Tension Feedback Setting - Mitsubishi Electric A800 Plus Series Function Manual

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Tension sensor feedback speed control details
4.5.1

Tension feedback setting

Set the target position for tension feedback.
Select the input method to the inverter (analog input terminal) for tension feedback input.
Pr.
Name
133
R101
PID action set point
(A611)
363
Dancer / tension sensor
R102
feedback input selection
Dancer / tension sensor
1227
feedback input filter time
R103
constant
PID set point (Pr.133)
• Set the set point for tension feedback in Pr.133 PID action set point.
Pr.133 setting
600%
+100%
500% (initial setting)
0%
400%
-100%
• Set a value according to the full scale value of the tension detector to be used and the corresponding output voltage. For
example, when tension feedback is input through terminal 1 and the tension sensor outputs 10 V for 100 N (full scale
value), set 530% in Pr.133 to set 30 N tension.
Set point
600%
530%
0 V
3 V
30 N
NOTE
• Set Pr.52 = "86" to monitor the tension feedback value on a percentage basis.
Tension feedback input selection (Pr.363)
• Use Pr.363 Dancer / tension sensor feedback input selection to select the input terminal for tension feedback.
Pr.363 setting
3
Terminal 2 (0 to 100%) (0 to 5 VDC)
4
Terminal 4 (20 to 100%) (4 to 20 mADC)
Terminal 1 (-100 to 100%) (0 to ±10 VDC)
5 (initial value)
6
Terminal 6 (FR-A8AZ) (-100 to 100%) (0 to ±10 VDC)
∗1
The input specification in the initial setting is indicated.
106
TENSION SENSOR FEEDBACK SPEED CONTROL
Initial value
500%
9999
0
Actual set point
10 V
Tension setting using
100 N
analog input value
Input terminal
∗1
Setting range
400 to 600%
Set the set point for tension feedback.
3
The measured value is input through terminal 2.
4
The measured value is input through terminal 4.
5
The measured value is input through terminal 1.
The measured value is input through terminal 6
6
(FR-A8AZ).
9999
No function
0
Without filter
Set the primary delay filter for the tension feedback
0.01 to 5 s
input value.
∗1
∗1
∗1
Description