Winding Diameter Calculation Setting; Block Diagram - Mitsubishi Electric A800 Plus Series Function Manual

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Winding diameter calculation setting

8.2
Winding diameter calculation setting
Purpose
To perform setting for winding
diameter calculation
To calculate the winding diameter
from the actual line speed
To select the actual line speed
input method
To select the line speed command
setting unit
To calculate the winding diameter
from the material thickness
To set the line speed command or
actual line speed to start winding
diameter calculation
To set a limit to the minimum/
maximum value of the winding
diameter calculation result
To output the signal when the
predetermined winding diameter is
reached
To store the present winding
diameter/length value
8.2.1

Block diagram

Winding/unwinding
Actual line speed
selection
Pr.1230
×
2
Accumulated amount
π
×
Motor rotations per minute
Setting determined by the
initial winding measurement
Clamping
X122-OFF
Pr.1247
X122-ON
Before the time elapsed
∗1
After clearing, the value becomes the minimum winding diameter when Pr.1230 = "0" (winding), and the maximum winding diameter when
Pr.1230 = "1" (unwinding).
160
WINDING DIAMETER COMPENSATION FUNCTION
Basic setting for winding
diameter calculation
Winding diameter
calculation using actual
line speed
Actual line speed input
selection
Line speed command
unit setting
Winding diameter
calculation using
material thickness
(thickness method)
Line speed at winding
diameter calculated
value activation
Minimum/maximum
winding diameter
Target winding diameter
achieved
Winding diameter /
winding length storage
Sampling
Pr.1245
Sampling
(about 5 ms)
Out of the
deadband
×
Gear ratio
Held
Within the deadband
Tension sensor feedback speed control /
Tension sensorless / tension sensor feedback
After the Pr.1248
setting time elapsed
Averaging
Pr.1249
Parameter to set
P.R000, P.R001,
P.R600, P.R601
P.R041, P.R050 to
P.R057, P.R201,
P.D101
P.R050
P.R201
P.R010 to P.R013
P.R040
P.R020 to P.R027
P.R420
P.R003 to P.R008,
P.R041, P.R420,
P.R421, P.R424
Actual line speed method
Actual line speed
D =
π
×
Line speed command value
Thickness method
D = Initial winding diameter±2
×
Number of motor shaft rotations
Dancer feedback
speed control
Initial
winding diameter
torque control
Clamping
Pr.1247 = 9999
Pr.1249 = 0
Pr.1235 to Pr.1242
Held
Pr.1249 = 0
Pr.1247 = 9999
Pr.1243, Pr.1244,
Pr.1247, Pr.1248
Pr.278 to Pr.284,
Pr.358, Pr.362,
Pr.384, Pr.1245
Pr.362
Pr.358
Pr.1231 to Pr.1234
Pr.1246
Pr.1235 to Pr.1242
Pr.648
Pr.645 to Pr.648,
Pr.1262 to Pr.1264,
Pr.1298, Pr.1299,
Pr.1346
Pr.1231 = 9999
×
Gear ratio
×
Material thickness
Pr.1231 = 9999
X109-OFF
X115-OFF
Held
X115-ON
Winding diameter
∗1
clear
X109-ON
Refer to
page
161
163
166
163
166
167
169
171
176
Winding diameter

Advertisement

Table of Contents
loading