Output Signal - Mitsubishi Electric A800 Plus Series Function Manual

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

9.2.2

Output signal

• To use output signals, assign them to Pr.190 to Pr.196 (output terminal function selection).
Output signal list
Pr.190 to Pr.196
setting
Positive
Negative
logic
logic
14
114
PID lower limit
15
115
PID upper limit
231
331
Break detection
Winding diameter
232
332
calculation
completion at start
Target winding
233
333
diameter achieved
Winding/unwinding
234
334
completion
Dancer position /
235
335
tension feedback
detection
236
336
Reel change ready
Line speed
237
337
acceleration
Line speed
238
338
deceleration
Average current
239
339
load detection
List of output signals with validity status by control mode (function)
Pr.190 to Pr.196
setting
Positive
Negative
logic
logic
14
114
PID lower limit
15
115
PID upper limit
231
331
Break detection
Winding diameter
232
332
calculation completion at
start
Target winding diameter
233
333
achieved
Winding/unwinding
234
334
completion
Dancer position / tension
235
335
feedback detection
236
336
Reel change ready
237
337
Line speed acceleration
238
338
Line speed deceleration
Average current load
239
339
detection
Signal name
Output when the dancer roll position or the roll tension value goes lower
FDN
than the limit determined by the setting of Pr.132 PID lower limit.
Output when the dancer roll position or the roll tension value goes higher
FUP
than the limit determined by the setting of Pr.131 PID upper limit.
Output when the dancer roll position or the roll tension becomes
Y231
abnormal due to a break.
Y232
Output when the diameter calculation is completed at an operation start.
Output when the diameter reaches the setting in Pr.648 Target winding
diameter or longer for winding.
Y233
Output when the diameter reaches the setting in Pr.648 Target winding
diameter or shorter for unwinding.
Output when the winding/unwinding length is equal to or more than the
value of determined by the settings of Pr.1264 Winding length
Y234
detection (lower 4 digits) and Pr.1346 Winding length detection
(upper 4 digits).
Output while the dancer roll position or the roll tension is within a range
Y235
determined by the setting of Pr.423 Dancer / tension sensor feedback
detection level. This signal is also output when the inverter is at a stop.
Output when the commanded line speed reaches the target line speed
Y236
while the reel change function is valid.
Output while the commanded line speed increases. The signal can be
Y237
input to the terminal to which the Inertia compensation acceleration
(X111) signal of the inverter for the driving shaft is assigned.
Output while the commanded line speed decreases. The signal can be
Y238
input to the terminal to which the Inertia compensation deceleration
(X112) signal of the inverter for the driving shaft is assigned.
Output when the output current average value reaches or exceeds 50%
Y239
of the inverter rated current. (This function is only available for the SND
rating.)
feedback
Signal name
FDN
FUP
Y231
Y232
Y233
Y234
Y235
Y236
Y237
Y238
Y239
ROLL TO ROLL FUNCTION RELATED PARAMETERS
Roll to roll dedicated I/O signal
Description
Tension
Dancer
Tension
sensor
sensorless
feedback
speed
torque
speed
control
control
control
Refer
to
page
74
74
74
171,
175
171
176
73,
107
90
69,
130
69,
130
7
Tension
sensor
Winding
feedback
diameter
torque
calculation
control
191
9

Advertisement

Table of Contents
loading

Table of Contents