Mitsubishi Electric A800 Plus Series Function Manual page 51

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Parameter setting procedure for dancer feedback speed control
Motor
Mitsubishi Electric standard
motor
Mitsubishi Electric high-
efficiency motor
Mitsubishi Electric constant-
torque motor
Mitsubishi Electric high-
performance energy-saving
motor with encoder
Vector control dedicated
motor
Other manufacturer's
standard motor
Other manufacturer's
constant-torque motor
NOTE
• If the SF-V5RU (other than the 1500 r/min series) is used, be sure to perform auto tuning after setting "1, 13, or 14" in Pr.71
and setting Pr.83 and Pr.84.
• If Pr.11 DC injection brake operation time = "0" or Pr.12 DC injection brake operation voltage = "0", offline auto tuning is
performed considering Pr.11 or Pr.12 is set to the initial value.
• If the star connection or delta connection is incorrectly selected in Pr.71 , Advanced magnetic flux vector control, Real
sensorless vector control and vector control are not performed normally.
• For tuning accuracy improvement, set the following parameters when the motor constants are known in advance.
First
Second
motor Pr.
motor Pr.
707
744
724
745
∗4
The setting is valid only when a value other than "9999" is set in both Pr.707 (Pr.744) and Pr.724 (Pr.745).
50
DANCER FEEDBACK SPEED CONTROL
SF-JR, SF-TH
SF-JR 4P 1.5 kW or lower
SF-HR
Others
SF-JRCA 4P, SF-TH
(constant-torque)
SF-HRCA
Other (SF-JRC, etc.)
SF-PR-SC
SF-V5RU (1500 r/min series)
SF-THY
SF-V5RU (other than the
1500 r/min series)
Name
Motor inertia (integer)
Motor inertia (exponent)
Motor constant
parameter mH, %,
parameter internal
and A unit setting
0 (initial value)
3 (4)
20
23 (24)
40
43 (44)
0 (initial value)
3 (4)
1
13 (14)
50
53 (54)
1
13 (14)
70
73 (74)
30
33 (34)
1
13 (14)
0 (initial value)
3 (4)
1
13 (14)
Mitsubishi Electric motor
(SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU)
9999 (initial value)
Pr.71 setting
Motor constant
Motor constant
parameter Ω, mΩ,
data setting
and A unit setting
5 (star connection
motor)
6 (delta connection
motor)
15 (star connection
motor)
16 (delta connection
motor)
Other motors
Motor inertia
∗4
Jm = Pr.707 × 10^(-Pr.724) (kg·m
2
)