3.3.1
Analog input signals and pulse train input
signals
• Refer to the following table and set the parameters to input the signals.
• For analog input terminals, calibration is available with maximum and minimum input values. Either voltage or current
signals are input through terminal 2 and terminal 4. Always calibrate the terminal after changing the input specification. For
details on selecting the input specification and calibrating input values, refer to the FR-A800 Instruction Manual (Detailed).
Parameter
Pr.363 Dancer / tension sensor
feedback input selection
Pr.361 Line speed command
input selection
Pr.362 Actual line speed input
selection
Pr.1285 Taper setting analog
input selection
Pr.364 Dancer tension setting
input selection
Parameter
Pr.363 Dancer / tension sensor
feedback input selection
Pr.361 Line speed command
input selection
Pr.362 Actual line speed input
selection
Pr.1285 Taper setting analog
input selection
Pr.364 Dancer tension setting
input selection
∗1
The FR-A8AZ plug-in option is required.
∗2
The FR-A8AP/FR-A8AL plug-in option or the FR-A8TP control terminal option is required.
∗3
The setting is valid when Pr.291="1, 11, 21, or 100".
NOTE
• The Pr.361 to Pr.364 (dedicated function selection) and Pr.1285 settings have higher precedence over the other assigned
terminal settings such as Pr.868, Pr.858, and Pr.406. (Example: When Pr.363="5", and Pr.868="0", terminal 1 is set to the
dancer signal input.)
• While tension sensorless torque control is valid, the following parameter settings are invalid: Pr.361 Line speed command
input selection, Pr.363 Dancer / tension sensor feedback input selection, and Pr.364 Dancer tension setting input
selection.
• The dedicated function parameters take the following precedence over each other. When two or more signals are assigned to
a terminal, a signal with lower precedence is ineffective.
Dancer signal input (Pr.363) > Actual line speed input (Pr.362) > Tension command input (Pr.804) > Line speed command
input (Pr.361
0) > Taper setting input (Pr.1285) > Dancer tension setting input (Pr.364) > Line speed command
compensation input > Line speed command input (Pr.361=0) = Speed command during speed control
• When Pr.361 Line speed command input selection="0" while tension sensorless torque control is valid, the line speed
command is input in the same way as the frequency command.
Analog input
Terminal 1
Terminal 2
(-10 to 10 V)
(0 to 5 V)
5
3
5
3
5
3
5
3
5
3
Single-phase pulse train input
Terminal JOG
FR-A8AL
1
7
∗3
1
7
∗3
Terminal 4
Terminal 6
(4 to 20 mA)
(-10 to 10 V)
4
6
4
6
4
6
4
6
4
6
Encoder pulse
Parameter
train input
input (Pr.360)
∗2
2
8
2
DANCER FEEDBACK SPEED CONTROL
Control block diagram
Refer to page
∗1
71
60
163
92,
124
92
Refer to page
71
60
163
92,
124
92