Pr.
Pr.
Name
group
Stall prevention operation level
23
H610
compensation factor at double
speed
24
D304
Multi-speed setting (4 speed to 7
to
to
speed)
27
D307
Multi-speed input compensation
28
D300
selection
Acceleration/deceleration
29
F100
pattern selection
30
E300
Regenerative function selection
31
H420
Frequency jump 1A
32
H421
Frequency jump 1B
33
H422
Frequency jump 2A
34
H423
Frequency jump 2B
35
H424
Frequency jump 3A
36
H425
Frequency jump 3B
37
M000
Speed display
41
M441
Up-to-frequency sensitivity
42
M442
Output frequency detection
Output frequency detection for
43
M443
reverse rotation
Second acceleration/
44
F020
deceleration time
45
F021
Second deceleration time
46
G010
Second torque boost
47
G011
Second V/F (base frequency)
Second stall prevention
48
H600
operation level
Second stall prevention
49
H601
operation frequency
Second output frequency
50
M444
detection
Second electronic thermal O/L
51
H010
relay
Operation panel main monitor
52
M100
selection
FM/CA terminal function
54
M300
selection
55
M040
Frequency monitoring reference
56
M041
Current monitoring reference
57
A702
Restart coasting time
58
A703
Restart cushion time
60
G030
Energy saving control selection
65
H300
Retry selection
Stall prevention operation
66
H611
reduction starting frequency
Number of retries at fault
67
H301
occurrence
68
H302
Retry waiting time
69
H303
Retry count display erase
70
G107
Special regenerative brake duty
71
C100
Applied motor
72
E600
PWM frequency selection
Parameter list (by parameter number)
Minimum
Setting range
setting
increments
0 to 200%, 9999
0.1%
0 to 590 Hz, 9999
0.01 Hz
0, 1
1
0 to 6
1
0 to 2, 10, 11, 20, 21,
100 to 102, 110, 111, 120,
1
121
0 to 590 Hz, 9999
0.01 Hz
0, 1 to 9998
1
0 to 100%
0.1%
0 to 590 Hz
0.01 Hz
0 to 590 Hz, 9999
0.01 Hz
0 to 3600 s
0.1 s
0 to 3600 s, 9999
0.1 s
0 to 30%, 9999
0.1%
0 to 590 Hz, 9999
0.01 Hz
0 to 400%
0.1%
0 to 590 Hz, 9999
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 500 A, 9999
0.01 A
∗2
0 to 3600 A, 9999
0.1 A
∗3
0, 5 to 14, 17 to 20,
22 to 36, 38, 40 to 46,
50 to 57, 61 to 64, 67,
1
71 to 74, 81 to 93, 97, 98,
100
1 to 3, 5 to 14, 17 to 19,
21, 22, 24, 26 to 28, 30,
32 to 34, 36, 46, 50, 61,
1
62, 70, 81, 82, 87 to 90,
92, 93, 97, 98
0 to 590 Hz
0.01 Hz
0 to 500 A
0.01 A
∗2
0 to 3600 A
0.1 A
∗3
0, 0.1 to 30 s, 9999
0.1 s
0 to 60 s
0.1 s
0, 4, 9
1
0 to 5
1
0 to 590 Hz
0.01 Hz
0 to 10, 101 to 110
1
0.1 to 600 s
0.1 s
0
1
0 to 100%
0.1%
0, 1, 3 to 6, 13 to 16, 20,
23, 24, 30, 33, 34, 40, 43,
1
44, 50, 53, 54, 70, 73, 74
0 to 15
∗2
1
0 to 6, 25
∗3
Initial value
Refer
to
FM
CA
page
9999
∗17
9999
∗17
0
∗17
0
∗17
0
∗17
9999
∗17
9999
∗17
9999
∗17
9999
∗17
9999
∗17
9999
∗17
0
∗17
10%
∗17
6 Hz
∗17
9999
∗17
5 s
∗17
9999
∗17
9999
∗17
9999
∗17
150%
∗17
0 Hz
∗17
30 Hz
∗17
∗2
9999
∗17
∗3
0
181
92,
1
181
60 Hz
50 Hz
∗17
Inverter rated
∗2
∗17
current
∗3
9999
∗17
1 s
∗17
0
∗17
0
∗17
60 Hz
50 Hz
∗17
0
∗17
1 s
∗17
0
∗17
0%
∗17
0
∗17
2
∗17
PARAMETER LIST
Customer
setting
2
11

Advertisement

Table of Contents
loading

Table of Contents