Parameter list (by parameter number)
Pr.
Pr.
group
Operation panel monitor
774
M101
selection 1
Operation panel monitor
775
M102
selection 2
Operation panel monitor
776
M103
selection 3
A682
778
4 mA input check filter
T054
Pulse increment setting for
799
M520
output power
800
G200
Control method selection
801
H704
Output limit level
802
G102
Pre-excitation selection
Constant output range torque
803
G210
characteristic selection
R300
Tension / Torque command
804
source selection
D400
805
D401
Torque command value (RAM)
Torque command value
806
D402
(RAM,EEPROM)
807
H410
Speed limit selection
Forward rotation speed limit/
808
H411
speed limit
Reverse rotation speed limit/
809
H412
reverse-side speed limit
Torque limit input method
810
H700
selection
811
D030
Set resolution switchover
812
H701
Torque limit level (regeneration)
813
H702
Torque limit level (3rd quadrant)
814
H703
Torque limit level (4th quadrant)
815
H710
Torque limit level 2
Torque limit level during
816
H720
acceleration
Torque limit level during
817
H721
deceleration
Easy gain tuning response level
818
C112
setting
819
C113
Easy gain tuning selection
820
G211
Speed control P gain 1
821
G212
Speed control integral time 1
822
T003
Speed setting filter 1
823
G215
Speed detection filter 1
∗9
Torque control P gain 1 (current
824
G213
loop proportional gain)
Torque control integral time 1
825
G214
(current loop integral time)
826
T004
Torque setting filter 1
827
G216
Torque detection filter 1
828
G224
Model speed control gain
Taper ratio setting input filter
829
R504
time constant
830
G311
Speed control P gain 2
831
G312
Speed control integral time 2
832
T005
Speed setting filter 2
833
G315
Speed detection filter 2
∗9
834
G313
Torque control P gain 2
835
G314
Torque control integral time 2
836
T006
Torque setting filter 2
837
G316
Torque detection filter 2
840
G230
Torque bias selection
841
G231
Torque bias 1
22
PARAMETER LIST
Name
Setting range
1 to 3, 5 to 14, 17 to 20, 22
to 36, 38, 40 to 46, 50 to
57, 61 to 64, 67, 71 to 74,
81 to 93, 97, 98, 100,
9999
0 to 10 s
0.1, 1, 10, 100, 1000 kWh
0 to 2, 9 to 12, 20,
100 to 102, 109 to 112
0 to 400%, 9999
0, 1
0 to 2, 10, 11
0 to 6
600 to 1400%
600 to 1400%
0 to 2
0 to 400 Hz
0 to 400 Hz, 9999
0 to 2
0, 1, 10, 11
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
1 to 15
0 to 2
0 to 1000%
0 to 20 s
0 to 5 s, 9999
0 to 0.1 s
0 to 500%
0 to 500 ms
0 to 5 s, 9999
0 to 0.1 s
0 to 1000%
0 to 5 s
0 to 1000%, 9999
0 to 20 s, 9999
0 to 5 s, 9999
0 to 0.1 s, 9999
0 to 500%, 9999
0 to 500 ms, 9999
0 to 5 s, 9999
0 to 0.1 s, 9999
0 to 3, 24, 25, 9999
600 to 1400%, 9999
Minimum
Initial value
setting
FM
CA
increments
1
9999
1
9999
1
9999
0.01 s
0 s
0.1 kWh
1 kWh
1
20
0.1%
9999
1
0
1
0
1
0
1%
1000%
1%
1000%
1
0
0.01 Hz
60 Hz
50 Hz
0.01 Hz
9999
1
0
1
0
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
1
2
1
0
1%
60%
0.001 s
0.333 s
0.001 s
9999
0.001 s
0.001 s
1%
100%
0.1 ms
5 ms
0.001 s
9999
0.001 s
0 s
1%
60%
0.01 s
0.02 s
1%
9999
0.001 s
9999
0.001 s
9999
0.001 s
9999
1%
9999
0.1 ms
9999
0.001 s
9999
0.001 s
9999
1
9999
1%
9999
Refer
Customer
to
setting
page
181
181
181
∗17
∗17
5
∗17
∗17
∗17
118
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
124
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17