APPENDIX

10.1
Differences in the functions from the
standard inverter
• The following functions of the FR-A800 standard inverter are deleted in the FR-A800-R2R inverter. Parameters, I/O signals,
and monitors relative to the deleted functions are also deleted or used differently in the FR-A800-R2R inverter.
Function
PM motor control
Second PID
Set point /
deviation /
measured value
PID control
input selection
PID pre-charge
function
PID display unit
SLEEP function
Dancer control
Position control
Orientation function
Pulse monitor selection
Adjustable 5 points V/F
Remote function
Automatic acceleration/
deceleration

Differences in the functions from the standard inverter

Parameter
Pr.373, Pr.702, Pr.706, Pr.711,
Pr.712, Pr.717, Pr.721, Pr.725,
Pr.738 to Pr.743, Pr.746, Pr.747,
Pr.788, Pr.791, Pr.792, Pr.998,
Pr.1002, Pr.1105, Pr.1412, Pr.1413
Pr.71 setting range change ("330,
333, 334, 8090, 8093, 8094, 9090,
9093, and 9094" are deleted.)
Pr.450 setting range change ("330,
333, 334, 8090, 8093, 8094, 9090,
9093, and 9094" are deleted.)
Pr.753 to Pr.758, Pr.765 to Pr.769,
Pr.1136 to Pr.1149
Pr.609, Pr.610
Pr.128 setting range change
("10, 11, 20, 21, 42, 43, 50, 51, 60, 61,
70, 71, 80, 81, 90, 91, 100, 101, 1000,
1001, 1010, 1011, 2000, 2001, 2010,
2011" are deleted.)
Pr.760 to Pr.764
Pr.759, C42 (Pr.934), C43 (Pr.934),
C44 (Pr.935), C45 (Pr.935)
Pr.575 to Pr.577
Pr.554 setting range change
("10 to 13" are deleted.)
Pr.1015 setting range change
("2, 10 to 12" are deleted.)
Pr.1134, Pr.1135
Pr.419 to Pr.421, Pr.423 to Pr.427,
Pr.429, Pr.446, Pr.464 to Pr.494,
Pr.1220 to Pr.1290,
Pr.1292 to Pr.1298
Pr.451 setting range change
("3 to 5, 13, 14, 103 to 105, 113, and
114" are deleted.)
Pr.800 setting range change
("3 to 5, 13, 14, 103 to 105, 113, and
114" are deleted.)
Pr.350 to Pr.358, Pr.360 to Pr.366,
Pr.393 to Pr.399, Pr.829
Pr.430
Pr.100 to Pr.109
Pr.71 setting range change
("2" is deleted.)
Pr.59
Pr.61 to Pr.64, Pr.292, Pr.293
Input
Output
signal
signal
∗1
∗2
IPM (57)
Y50 (50)
Y52 (52)
Y54 (54)
X73 (73)
FDN2 (200)
X78 (78)
FUP2 (201)
X79 (79)
RL2 (202)
X80 (80)
PID2 (203)
SLEEP2 (204)
Y205 (205)
X14 (14)
Y49 (49)
X77 (77)
Y51 (51)
Y53 (53)
SLEEP (70)
Y36 (36)
CLRN (59)
MEND (38)
NP (68)
ZA (56)
CLR (69)
FP (60)
X76 (76)
PBSY (61)
X84 (84)
ZP (63)
X87 (87)
RDY (84)
ORA (27)
X22 (22)
ORM (28)
Monitor
∗3
Second PID set point (92)
Second PID measured
value (93)
Second PID deviation (94)
Second PID measured
value 2 (95)
Second PID manipulated
amount (96)
Dancer main set speed (97)
Position pulse (19)
Position command (lower)
(26)
Position command (upper)
(27)
Current position (lower) (28)
Current position (upper) (29)
Droop pulse (lower) (30)
Droop pulse (upper) (31)
Multi-revolution counter (75)
Orientation status (22)
195
APPENDIX
10