Changing the output frequency setting of the frequency setting
potentiometer (bias and gain of frequency setting voltage (current))
5.1 Changing the output frequency setting of the
frequency setting potentiometer
(bias and gain of frequency setting voltage (current))
POINT
Pr. 38, Pr. 39 and calibration parameters "C1 to C7" can be made to be read by
setting "1" (extended function parameter valid) in Pr. 30 "extended function
display selection".
The bias/gain of the frequency setting voltage (current) may be adjusted in any of the
following methods:
(1) Changing the highest frequency
(2) Adjusting the deviation of the highest frequency from the Pr. 38 (Pr. 39) setting
(2)-1) Make adjustment with a voltage applied across terminals 2-5 (with a current
flowing across terminals 4-5)
(2)-2) Make adjustment at any point without a voltage applied across terminals 2-5
(without a current flowing across terminals 4-5) (For the setting method, refer
to the instruction manual (detailed).)
28