Parameter list (by parameter number)
Pr.
Pr.
group
73
T000
Analog input selection
74
T002
Input filter time constant
Reset selection/disconnected
PU detection/PU stop selection
75
E100
Reset selection
E101
Disconnected PU detection
E102
PU stop selection
E107
Reset limit
76
M510
Fault code output selection
77
E400
Parameter write selection
Reverse rotation prevention
78
D020
selection
Operation mode
79
D000
selection
80
C101
Motor capacity
81
C102
Number of motor poles
82
C125
Motor excitation current
83
C104
Rated motor voltage
84
C105
Rated motor frequency
85
G201
Excitation current break point
Excitation current low-speed
86
G202
scaling factor
Speed control gain (Advanced
89
G932
magnetic flux vector)
90
C120
Motor constant (R1)
91
C121
Motor constant (R2)
92
C122
Motor constant (L1)
93
C123
Motor constant (L2)
94
C124
Motor constant (X)
95
C111
Online auto tuning selection
96
C110
Auto tuning setting/status
Second acceleration time for
100
R253
line speed command
Second deceleration time for
101
R254
line speed command
Third acceleration time for line
102
R255
speed command
Third deceleration time for line
103
R256
speed command
Third acceleration/deceleration
110
F030
time
111
F031
Third deceleration time
112
G020
Third torque boost
113
G021
Third V/F (base frequency)
Third stall prevention operation
114
H602
level
Third stall prevention operation
115
H603
frequency
Third output frequency
116
M445
detection
PU communication station
117
N020
number
12
PARAMETER LIST
Name
0 to 7, 10 to 17
0 to 8
0 to 3, 14 to 17, 1000 to
1003, 1014 to 1017
0 to 3, 14 to 17, 100 to
103, 114 to 117, 1000 to
1003, 1014 to 1017, 1100
to 1103, 1114 to 1117
0 to 3
0, 1
0
∗2
0, 1
0 to 2
0 to 2
0 to 2
0 to 4, 6, 7
Simple
Simple
Simple
0.4 to 55 kW, 9999
0 to 3600 kW, 9999
2, 4, 6, 8, 10, 12, 9999
0 to 500 A, 9999
0 to 3600 A, 9999
0 to 1000 V
10 to 400 Hz, 9999
0 to 400 Hz, 9999
0 to 300%, 9999
0 to 200%, 9999
0 to 50 Ω, 9999
0 to 400 mΩ, 9999
0 to 50 Ω, 9999
0 to 400 mΩ, 9999
0 to 6000 mH, 9999
0 to 400 mH, 9999
0 to 6000 mH, 9999
0 to 400 mH, 9999
0 to 100%, 9999
0 to 2
0, 1, 11, 101
0 to 3600 s
0 to 3600 s
0 to 3600 s
0 to 3600 s
0 to 3600 s, 9999
0 to 3600 s, 9999
0 to 30%, 9999
0 to 590 Hz, 9999
0 to 400%
0 to 590 Hz
0 to 590 Hz
0 to 31
Minimum
Setting range
setting
increments
1
1
∗2
∗3
1
∗3
1
1
1
1
0.01 kW
∗2
0.1 kW
∗3
1
0.01 A
∗2
0.1 A
∗3
0.1 V
0.01 Hz
0.01 Hz
0.1%
0.1%
0.001 Ω
∗2
0.01 mΩ
∗3
0.001 Ω
∗2
0.01 mΩ
∗3
0.1 mH
∗2
0.01 mH
∗3
0.1 mH
∗2
0.01 mH
∗3
0.1%
0.01%
1
1
0.1 s
0.1 s
0.1 s
0.1 s
0.1 s
0.1 s
0.1%
0.01 Hz
0.1%
0.01 Hz
0.01 Hz
1
Initial value
Refer
FM
CA
page
1
1
14
0
1
0
0
0
0
0
9999
9999
9999
200 V
∗7
400 V
∗8
9999
9999
9999
9999
∗2
9999
∗3
∗2
9999
∗3
∗2
9999
∗3
∗2
9999
∗3
∗2
9999
∗3
0
0
15 s
69
15 s
69
15 s
69
15 s
69
9999
9999
9999
9999
150%
0 Hz
60 Hz
50 Hz
0
Customer
to
setting
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17
∗17