Mitsubishi Electric A800 Plus Series Function Manual page 20

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Pr.
Pr.
Name
group
475
R124
Third PID differential time
Third PID proportional band for
476
R125
values below set point
Third PID integral time for
477
R126
values below set point
Third PID differential time for
478
R127
values below set point
479
R128
Fourth PID proportional band
480
R129
Fourth PID integral time
481
R130
Fourth PID differential time
Fourth PID proportional band for
482
R131
values below set point
Fourth PID integral time for
483
R132
values below set point
Fourth PID differential time for
484
R133
values below set point
485
R149
Integral control activation
486
R140
Deviation A
487
R141
Deviation B
488
R142
Deviation C1
489
R143
Deviation C2
490
R144
PID gain A
491
R145
PID gain B
492
R146
PID gain C1
493
R147
PID gain C2
494
R148
PID gain D
495
M500
Remote output selection
496
M501
Remote output data 1
497
M502
Remote output data 2
PLC function flash memory
498
A804
clear
Stop mode selection at
502
N013
communication error
503
E710
Maintenance timer 1
Maintenance timer 1 warning
504
E711
output set time
505
M001
Speed setting reference
S-pattern time at a start of
516
F400
acceleration
S-pattern time at a completion of
517
F401
acceleration
S-pattern time at a start of
518
F402
deceleration
S-pattern time at a completion of
519
F403
deceleration
MODBUS RTU communication
539
N002
check time interval
USB communication station
547
N040
number
USB communication check time
548
N041
interval
549
N000
Protocol selection
NET mode operation command
550
D012
source selection
PU mode operation command
551
D013
source selection
552
H429
Frequency jump range
553
A603
PID deviation limit
554
A604
PID signal operation selection
555
E720
Current average time
556
E721
Data output mask time
Current average value monitor
557
E722
signal output reference current
560
A712
Second frequency search gain
561
H020
PTC thermistor protection level
Parameter list (by parameter number)
Minimum
Setting range
setting
increments
0.01 to 10 s, 9999
0.01 s
0.1 to 1000%, 9999
0.1%
0.1 to 3600 s, 9999
0.1 s
0.01 to 10 s, 9999
0.01 s
0.1 to 1000%, 9999
0.1%
0.1 to 3600 s, 9999
0.1 s
0.01 to 10 s, 9999
0.01 s
0.1 to 1000%, 9999
0.1%
0.1 to 3600 s, 9999
0.1 s
0.01 to 10 s, 9999
0.01 s
0 to 3
1
400.1 to 600%
0.1%
400 to 599.9%
0.1%
400.1 to 599.9%, 9999
0.1%
400.1 to 599.9%, 9999
0.1%
0.1 to 1000%, 9999
0.1%
0.1 to 1000%, 9999
0.1%
0.1 to 1000%, 9999
0.1%
0.1 to 1000%, 9999
0.1%
0.1 to 1000%, 9999
0.1%
0, 1, 10, 11
1
0 to 4095
1
0 to 4095
1
0, 9696 (0 to 9999)
1
0 to 2, 11, 12
1
0 (1 to 9998)
1
0 to 9998, 9999
1
1 to 590 Hz
0.01 Hz
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 s
0 to 999.8 s, 9999
0.1 s
0 to 31
1
0 to 999.8 s, 9999
0.1 s
0, 1
1
0, 1, 9999
1
1 to 3, 9999
1
0 to 30 Hz, 9999
0.01 Hz
0.0 to 100.0%, 9999
0.1%
0 to 3
1
0.1 to 1 s
0.1 s
0 to 20 s
0.1 s
0 to 500 A
0.01 A
∗2
0 to 3600 A
0.1 A
∗3
0 to 32767, 9999
1
0.5 to 30 kΩ, 9999
0.01 kΩ
Initial value
Refer
to
FM
CA
page
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
0
85
600%
86
400%
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
0
∗17
0
∗17
0
∗17
0
∗17
0
∗17
0
∗17
9999
∗17
60 Hz
50 Hz
∗17
0.1 s
∗17
0.1 s
∗17
0.1 s
∗17
0.1 s
∗17
9999
∗17
0
∗17
9999
∗17
0
∗17
9999
∗17
9999
∗17
9999
∗17
9999
∗17
0
76
1 s
∗17
0 s
∗17
Inverter rated
∗2
∗17
current
∗3
9999
∗17
9999
∗17
PARAMETER LIST