2.2 Power Supply Specifications

2.2.1 AC Power Supply
Item
Rated voltage
Voltage regulation range
Inrush current
Momentary power off time
Frequency
Leakage current
Internal power supply part
Guaranteed life
Fuse
Insulation system
Terminal screw
2.2.2 Service Power Supply for Input (Output) (AC Power Supply Type Only)
Item
Rated output voltage
Voltage regulation range
Rated output current
Overcurrent protection
Note)
function
Terminal screw
Note) This is a function to protect overcurernt temporarily, which protects the output short-circuit. If the
short-circuit is detected, all the power supply for the PLC will be turned off. If a current load that is
out of the specifications is connected and the overloaded status continues, it may lead to damages.
2.2.3 DC Power Supply
Item
Rated voltage
Voltage regulation range
Inrush current
Momentary power off time
Internal power supply part
Guaranteed life
Fuse
Insulation system
Terminal screw
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
C14
100 to 240 V AC
85 to 264 V AC
40 A or less (at 240 V AC, 25 °C)
10 ms (when using 100 V AC)
50/60 Hz (47 to 63 Hz)
0.75 mA or less between input and protective earth terminals
20,000 hours (at 55 °C)
Built-in (Cannot be replaced)
Transformer insulation
M3
C14
24 V DC
21.6 to 26.4 V DC
0.15 A
Available
M3
C14
24 V DC
20.4 to 28.8 V DC
12 A or less (at 25 °C)
10 ms
20,000 h (at 55 °C)
Built-in (Cannot be replaced)
Transformer insulation
M3
Specifications
C30R/C60
45 A or less (at 240 V AC, 25 °C)
Specifications
C30/C60
0.4 A
Specifications
C30/C60