High-speed counter/pulse output control flag area of FP-X Ry type
High-speed counter control code monitor area
High-speed counter
Channel No.
ch0
ch1
ch2
ch3
ch4
ch5
ch6
ch7
ch8
ch9
chA
chB
Elapsed value write and read instruction (F1)
• This instruction changes or reads the elapsed value of the high-speed counter.
• Specify this instruction together with the special data register DT90300.
• The elapsed value is stored as 32-bit data in the combined area of special data registers DT90300 and
DT90301.
• Use this F1 (DMV) instruction to set the elapsed value.
Example 1: Writing the elapsed value
Example 2: Reading the elapsed value
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Control code monitor area
FP-X Ry type
DT90360
DT90361
DT90362
DT90363
DT90364
DT90365
DT90366
DT90367
DT90368
DT90369
DT90370
DT90371
Set the initial value of K3000 in the high-speed
counter.
Read the elapsed value of the high-speed
counter and copies it to DT100 and DT101.
• The area DT90052 for writing channels
and control codes is allocated as shown in
the left figure.
• Control codes written with an F0 (MV)
instruction are stored by channel in
special data registers DT90360 to
DT90373.
Note) In the reset input setting, the reset
input (X102 or X202) allocated in the
high-speed counter setting of the
system registers are defined to
"enable/disable".
FP-X Tr type
DT90370
DT90371
DT90372
DT90373
DT90374
DT90375
DT90376
DT90377
-
-
-
-