Panasonic AFPX-C30R User Manual page 322

Fp-x series
Hide thumbs Also See for AFPX-C30R:
Table of Contents

Advertisement

10.2 Function Specifications and Restricted Items
10.2.1 Specifications
High-speed counter function
High-speed counter by the input of the main unit
Channel No.
CH0
CH1
CH2
[Single phase]
CH3
Incremental,
Decremental
CH4
CH5
CH6
CH7
CH0
[2-phase]
CH2
2-phase input
One input
CH4
CH6
Related instructions:
F0(MV) :High-speed counter control
F1(DMV) :Read/write of elapsed value of high-speed counter
F166(HC1S) :Target value match on
F167(CH1R) :Target value match off
Note1)
Reference: For information on minimum input pulse width,
Note2) When using the high-speed counter of the main unit only
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Memory area being used
Input contact
Control
flag
X0
R9110
X1
R9111
X2
R9112
X3
R9113
X4
R9114
X5
R9115
X6
R9116
X7
R9117
X0
R9110
X1
X2
R9112
X3
X4
R9114
X5
X6
R9116
X7
<10.3.3 Minimum Input Pulse Width>.
Elapsed
Target
value area
value area
DT90300
DT90302
DT90301
DT90303
DT90304
DT90306
DT90305
DT90307
DT90308
DT90310
DT90309
DT90311
DT90312
DT90314
DT90313
DT90315
DT90316
DT90318
DT90317
DT90319
DT90320
DT90322
DT90321
DT90323
DT90324
DT90326
DT90325
DT90327
DT90328
DT90330
DT90329
DT90331
DT90300
DT90302
DT90301
DT90303
DT90308
DT90310
DT90309
DT90311
DT90316
DT90318
DT90317
DT90319
DT90324
DT90326
DT90325
DT90327
Performance specifications
Maximum
Minimum input
counting
Note1)
pulse width
speed
µ
10 kHz
50
s
µ
5 kHz
100
s
Note2)