Environmental Specifications; Electrical Specifications; Structural Specifications - JCM GLOBAL RDM-100 Series Integration Manual

Retail deposit module
Table of Contents

Advertisement

Environmental Specifications

Operating Temperature:
Storage Temperature:
Relative Operating Humidity:
Relative Storage Humidity:
Visible Light Sensitivity:
Installation:
*. Depends on hydrothermal conditions.
Hydrothermal Condition Table
100
90
80
70
Allowable
60
50
Operating Temperature
40
and Humidity Range
30
20
10
0
0
20
10
Temperature [ºC]

Electrical Specifications

*
Supply Voltage
:
Current Consumption:
*. Use a Current Source Limiting Power Supply

Structural Specifications

Weight:
Mounting:
Outside Dimensions:
P/N 960-000186R_Rev. A {EDP #253995}
RDM-100™ Series Retail Deposit Module
Table 3 RDM-100 Environmental Specifications
+5ºC to +45ºC (41ºF to 113ºF)
-20ºC to +60ºC (-4ºF to 140ºF)
20% to 80% RH (non-condensed)
10% to 90% RH (non-condensed)
Avoid light on the Banknote Insertion/Return Slots having an Illumination
index of 3000 Lux or less and if warm color incandescent light range 
radiant of 0 to 45 degrees from all sides or if light from a Mercury Lamp a
radiant angle between 10 to 85 degrees
Indoors Only (Built-in)
Fixture material/shape must endure 55kg weight without distortion
5ºC/40RH%
40ºC/80RH%
45ºC/40RH%
10ºC/20RH%
30
40
50
Table 4 RDM-100 Electrical Specifications
24V DC ±10%
24V DC
Standby = 0.4A
Operation = 3.2A
Peak = 4.7A
Table 5 RDM-100 Structural Specifications
Unit: Approximately 17kg (37.48lbs.)
Built-in
See "Entire Unit Outside Dimensions" on page 33 of this Manual
*
*