Information About Equipment Handling Of Air-Cooled Units; Customer Terminal Block -X55 - Siemens SINAMICS G130 Engineering Manual

Sinamics - low voltage sinamics drives
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

SINAMICS S120 Cabinet Modules
Engineering Information

7.2.3 Information about equipment handling of air-cooled units

7.2.3.1

Customer terminal block -X55

Overview
The customer terminal block -X55 is the signal interface of the Cabinet Module to the higher level control and collects
a range of internal cabinet signals on a central terminal block module mounted near the bottom of the Cabinet
Module.
The customer terminal block -X55 is used in Cabinet Modules of type Motor Module in Chassis format and, in
conjunction with a CU320-2 Control Unit, in Cabinet Modules of type Basic Line Module, Smart Line Module, Active
Line Module and Booksize Cabinet Kits.
Design of the customer terminal block -X55 on air-cooled SINAMICS S120 Cabinet Modules
Terminals -X122, -X132, -X41 and -X46 are provided for connection of customer signal cables. The connectable
cable cross-section is 1.5 mm² for both solid and stranded cables.
Terminals -X1 to -X4 are assigned internally in the cabinet depending on how the Cabinet Module is equipped
(without CU320-2 or with CU320-2 DP (option K90) or CU320-2 PN (option K95)).
The customer terminal block -X55 includes:
12 digital inputs DI
(-X122, -X132)
8 bidirectional inputs / outputs DI / DO
(-X122, -X132)
Safety functions
"Safe Torque Off / Safe Stop 1"
(-X41)
Temperature sensor KTY84, PT1000,
PT100, PTC
(-X41)
Safe Brake Adapter
(-X46)
1)
Connection is provided on the separate customer terminal block -X55.1 or -X55.2 on Booksize Cabinet Kits
SINAMICS Engineering Manual – November 2015
404/528
Ó Siemens AG
Motor Modules Chassis
With CU320-2
Without CU320-2
(option K90 or K95)
X
X
X
X
X
Line Modules / Booksize Cabinet Kits
With CU320-2
(option K90 or K95)
-
X
-
X
1)
-
-
1)
X
-
X
-
Without CU320-2
-
-
1)
-
1)
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g150Sinamics s120Sinamics s150

Table of Contents