The possible continuous braking power P
table of unit-specific technical data. They refer to the upper response thresholds, i.e. to V
voltages of 380 V to 480 V and to V
thresholds, the braking power must be reduced in proportion to V
The table below states the key technical data for SINAMICS S120 Motor Modules in their application as 3-phase
Braking Modules.
S120 Motor Modules
in
standard application
Output
Rated
Continuous
power
output
braking
at 400 V
current
current
or 690 V
I
I
rated
rated-Brake
[ kW ]
[ A ]
380 V – 480 V 3AC or 510 V – 720 V DC
110
210
132
260
160
310
200
380
250
490
315
605
400
745
450
840
560
985
710
1260
800
1405
500 V – 690 V 3AC or 675 V – 1035 V DC
75
85
90
100
110
120
132
150
160
175
200
215
250
260
315
330
400
410
450
465
560
575
710
735
800
810
900
910
1000
1025
1200
1270
1500
1560
Technical data of S120 Motor Modules in their application as 3-phase Braking Modules
Dimensioning of the braking resistors
The formula below defines the required limits of the resistance values R
resistors. Allowance for the increase in resistance as a function of load (up to 30 %) must be included in the
calculation:
and the peak braking power P
rated-Brake
= 1158 V at line supply voltages of 500 V to 690 V. For other response
DC-max
S120 Motor Modules in application as 3-phase Braking Modules
Base
Base
load
load
braking
braking
current
current
I
I
L-Brake
H-Brake
[ A ]
[ A ]
[ A ]
210
205
178
255
245
229
290
283
259
340
331
304
450
438
402
545
531
414
680
662
520
800
781
667
900
877
786
1215
1186
1087
1365
1331
1221
85
80
76
100
95
89
115
110
103
144
136
129
175
171
157
215
208
192
255
245
229
290
281
246
400
390
358
450
437
403
515
502
460
680
657
608
805
785
720
905
875
810
1020
995
913
1230
1191
1002
R
< R
BR-min
max-Brake
.
DC-Brake
Maximum
Upper
Continuous
braking
response
braking
current
threshold
power
I
V
(upper
max-Brake
DC-max
response
threshold)
P
rated-Brake
[ A ]
[ V ]
[ kW ]
307
774
368
774
424
774
497
774
657
774
797
774
993
774
1171
774
1316
774
1779
774
1996
774
120
1158
142
1158
165
1158
204
1158
255
1158
312
1158
368
1158
422
1158
585
1158
656
1158
752
1158
985
1158
1178
1158
1313
1158
1493
1158
1787
1158
in preparation
of the three star-connected braking
BR
< R
.
BR
BR-max
SINAMICS Engineering Manual – November 2015
SINAMICS S120
Engineering Information
are included in the following
= 774 V at line supply
DC-max
Peak braking
Minimum
power
braking
(upper
resistance
response
(cold state)
threshold)
P
max-Brake
[ kW ]
197
288
239
345
272
398
319
466
422
617
511
748
638
932
751
1099
845
1235
1140
1669
1281
1873
119
168
140
199
161
232
202
286
246
358
302
438
358
517
407
592
562
821
632
921
723
1056
955
1383
1130
1654
1271
1843
1432
2096
1727
2509
375/528
Ó Siemens AG
R
BR-min
[ Ω ]
1.02
0.85
0.74
0.63
0.48
0.39
0.32
0.27
0.24
0.18
0.16
3.90
3.30
2.84
2.29
1.84
1.50
1.27
1.11
0.80
0.71
0.62
0.48
0.40
0.36
0.31
0.26