Siemens SINAMICS G130 Engineering Manual page 259

Sinamics - low voltage sinamics drives
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

The Advanced Operator Panel AOP30 belongs to the standard scope of supply of SINAMICS G150 and S150
converter cabinet units. It is available as an optional system component for SINAMICS G130 converter Chassis units
and for the modular cabinet units SINAMICS S120 Cabinet Modules.
Basically it is also possible to use the AOP30 on units in the modular system SINAMICS S120 in Chassis format,
although certain restrictions apply to the operation of multiple drives / axes on a single CU320-2 Control Unit because
only one AOP30 panel can be connected per Control Unit.
Advanced Operator Panel AOP30
The AOP30 communicates over a serial interface at connector X540. The AOP30 supports the RS232 and RS485
standards. Standard RS232 is employed for the purpose of communication between the AOP30 operator panel and
the CU320-2 Control Unit, where the AOP30 functions as the master and the CU320-2 as the slave. Standard RS485
is employed for the purpose of communication with devices in the SINAMICS DCM range.
The AOP30 is an operator panel with a graphic display and membrane keyboard. It is suitable for mounting in cabinet
doors with a thickness of between 2 mm and 4 mm.
Because the RS232 standard is employed for communication, the connecting cable between the AOP30 and the
CU320-2 Control Unit should not exceed 10 m. The risk of communication errors cannot be precluded if longer cables
are used.
Dimensions of the Advanced Operator Panel AOP30
General Engineering Information for SINAMICS
Key assignment:
SINAMICS Engineering Manual – November 2015
Engineering Information
§
Functions
§
Menu
§
Operating / Parameterizing lock
§
Numerical keypad
§
Local / Remote switchover
§
ON/OFF
Clockwise / Counter-clockwise switchover
§
§
Jog
§
Setpoint increase / decrease
Features
§
Display with green
backlighting,
resolution: 240 x 64 pixels
§
26-key touch-sensitive
keypad
§
Connection for a 24 V DC
power supply (connector
X524)
§
Interface RS232 / RS485
(connector X540)
§
Time and date memory
powered by internal battery
backup
4 LEDs indicate the
§
operating status of the drive
unit:
– RUN green
– ALARM yellow
– FAULT red
– LOCAL / REMOTE green