Technical data of the braking resistors
Order No.
Unit
P
kW
DB
(Rated power)
P15
kW
(Maximum power)
Resistor
W
Max. current
A
Cable entry
Power connection
Max. connectable
mm²
cable cross-section
Degreee of protection
Width x Height x Depth mm
Approx. Weight
kg
Fits to the Braking
Module with order
number
6.8.3

SINAMICS S120 Motor Modules as 3-phase Braking Modules

Design
SINAMICS S120 Motor Modules in Chassis format (air-cooled and liquid-cooled) can be used as 3-phase Braking
Modules. Their application as a Braking Module is recommended whenever very high braking powers, particulary
extremely high continuous braking powers, are required.
Motor Modules can be used as Braking Modules only for less dynamic braking processes because, at about 4 to
5 ms, their response time is 3 times as long as the response time of the Braking Modules designed for mounting in
units in Chassis format, and of the Central Braking Modules included in the SINAMICS S120 Cabinet Modules
product spectrum. These have a response time of only 1 to 2 ms.
SINAMICS S120 Motor Modules operating as 3-phase Braking Modules are connected to the DC busbar, protected
and precharged in the same way as Motor Modules used for their standard purpose. Where possible, they should be
positioned within the drive configuration at the point at which the highest quantity of regenerative energy is fed into
the DC busbar, i.e. if possible next to the Motor Modules which regenerate the most energy.
Drive configuration comprising multiple S120 Motor Modules and one S120 Motor Module as a Braking Module
510 V – 720 V DC
6SL3000-
6SL3000-
1BE31-
1BE32-
3AA0
5AA0
25
50
125
250
4.4 ± 7.5%
2.2 ± 7.5%
189
378
Cable gland
Cable gland
M50
M50
Bolt
Bolt
M8
M8
50
70
IP20
IP20
740 x 605 x
810 x 1325 x
485
485
50
120
6SL3300-
6SL3300-
1AE31-
1AE32-
3AA0
5 . A0
SINAMICS Engineering Manual – November 2015
Engineering Information
675 V – 900 V DC
6SL3000-
6SL3000-
1BF31-
1BF32-
3AA0
5AA0
25
50
125
250
6.8 ± 7.5%
3.4 ± 7.5 %
153
306
Cable gland
Cable gland
M50
M50
Bolt
Bolt
M8
M8
50
70
IP20
IP20
740 x 605 x
810 x 1325 x
485
485
50
120
6SL3300-
6SL3300-
1AF31-
1AF32-
3AA0
5 . A0
SINAMICS S120
890 V – 1035 V DC
6SL3000-
6SL3000-
1BH31-
1BH32-
3AA0
5AA0
25
50
125
250
9.8 ± 7.5%
4.9 ± 7.5%
125
255
Cable gland
Cable gland
M50
M50
Bolt
Bolt
M8
M8
50
70
IP20
IP20
740 x 605 x
810 x 1325 x
485
485
50
120
6SL3300-
6SL3300-
1AH31-
1AH32-
3AA0
5 . A0
373/528