Rated output current
Output power
at
current derating factor
690 V
with pulse frequency of
1.25 kHz
500 V – 690 V 3AC
75 kW
85 A
90 kW
100 A
110 kW
120 A
132 kW
150 A
160 kW
175 A
200 kW
215 A
250 kW
260 A
315 kW
330 A
400 kW
410 A
450 kW
465 A
560 kW
575 A
710 kW
735 A
800 kW
810 A
900 kW
910 A
1000 kW
1025 A
1200 kW
1270 A
SINAMICS S150: Permissible output current (current derating factor) as a function of pulse frequency (continued)
Pulse frequency
Maximum attainable output frequency (rounded numerical values)
1.25 kHz
2.00 kHz
2.50 kHz
≥ 4.00 kHz
Maximum attainable output frequency as a function of pulse frequency
in operation with factory-set current controller clock cycles
Permissible output current as a function of ambient temperature
SINAMICS S150 converters and associated system components are rated for an ambient temperature of 40 °C and
installation altitudes of up to 2000 m above sea level. The output current of SINAMICS S150 converters must be
reduced (current derating) if they are operated at ambient temperatures above 40 °C. SINAMICS S150 cabinet units
are not permitted to operate at ambient temperatures in excess of 50 °C. The following tables specify the permissible
output current as a function of ambient temperature for the different degrees of protection.
Installation altitude
Current derating factor
above sea level
at an ambient temperature (inlet air) of
m
0 ... 2000
Current derating factors as a function of ambient temperature (inlet air) for SINAMICS S150 converter cabinet units
in degrees of protection IP20, IP21, IP23 and IP43
Installation altitude
Current derating factor
above sea level
at an ambient temperature (inlet air) of
m
0 ... 2000
Current derating factors as a function of ambient temperature (inlet air) for SINAMICS S150 converter cabinet units
in degree of protection IP54
SINAMICS Engineering Manual – November 2015
482/528
Ó Siemens AG
or
2.0 kHz
2.5 kHz
93 %
89 %
92 %
88 %
92 %
88 %
90 %
84 %
92 %
87 %
92 %
87 %
92 %
88 %
89 %
82 %
89 %
82 %
92 %
87 %
91 %
85 %
87 %
79 %
97 %
95 %
92 %
87 %
91 %
86 %
87 %
79 %
100 Hz
160 Hz
200 Hz
300 Hz
20 °C
25 °C
20 °C
25 °C
Current derating factor
with pulse frequency of
4.0 kHz
5.0 kHz
71 %
60 %
71 %
60 %
71 %
60 %
66 %
55 %
70 %
60 %
70 %
60 %
71 %
60 %
65 %
55 %
65 %
55 %
67 %
55 %
64 %
50 %
64 %
55 %
71 %
55 %
67 %
55 %
64 %
50 %
55 %
40 %
30 °C
35 °C
100 %
30 °C
35 °C
100 %
7.5 kHz
8.0 kHz
40 %
40 %
40 %
35 %
40 %
40 %
40 %
40 %
35 %
35 %
35 %
25 %
35 %
33 %
30 %
25 %
40 °C
45 °C
93.3 %
40 °C
45 °C
93.3 %
86.7 %
50 °C
86.7 %
50 °C
80.0 %