Foreword
Engineering Information
To all SINAMICS customers!
This engineering manual is supplementary to the SINAMICS Catalogs D 11 and D 21.3 and is designed to provide
additional support to users of SINAMICS converters. It focuses on drives with units in Chassis and Cabinet format in
the output power range ≥ 75 KW and operating in vector control mode (drive objects of vector type).
All information in this engineering manual refers to device variants equipped with the following hardware and
software:
·
Power unit with Control Interface Module CIM (order number ending in 3, e.g. 6SL3310-1GE38-4AA3)
·
CU320-2 Control Unit
·
Firmware version 4.3 or higher
The engineering manual contains a general analysis of the fundamental principles of variable-speed drives as well as
detailed system descriptions and specific information about the following units in the SINAMICS equipment range:
·
Converter Chassis Units SINAMICS G130 (Catalog D 11)
·
Converter Cabinet Units SINAMICS G150 (Catalog D 11)
·
Modular Chassis Units SINAMICS S120 (Catalogs D 21.3
and PM 21 / "SINAMICS S120 drive system")
·
Modular Cabinet Units SINAMICS S120 Cabinet Modules (Catalog D 21.3)
·
Converter Cabinet Units SINAMICS S150 (Catalog D 21.3)
This engineering manual is divided into different chapters.
The first chapter "Fundamental Principles and System Description" focuses on the physical fundamentals of electrical
variable-speed three-phase AC drives and provides general system descriptions of products in the SINAMICS range.
The second chapter "EMC Installation Guideline" gives an introduction to the subject of Electromagnetic Compatibility
(EMC), and provides all information required to engineer and install drives with the aforementioned SINAMICS
devices in an EMC-compliant manner.
The following chapters, which describe how to engineer SINAMICS G130, G150, S120 Built-in units, S120 Cabinet
Modules and S150, focus on subjects relating to specific units in more detail than the general system descriptions.
This engineering manual can and should only be viewed as a supplement to catalogs D 11, D 21.3 and PM 21 /
"SINAMICS S120 drive system". The document does not therefore contain any ordering data. The manual is
available only in electronic form in German or English.
The information of this manual is aimed at technically qualified and trained personnel. The configuring engineer is
responsible for assessing whether the information provided is sufficiently comprehensive for the application in
question and, therefore, assumes overall responsibility for the whole drive or the whole system.
The information provided in this engineering manual contains descriptions or characteristics of performance which in
case of actual use do not always apply as described, or which may change as a result of further development of the
products.
The desired performance characteristics are firmly binding only if expressly agreed upon in the contract.
Availability and technical specifications are subject to change without prior notice.
EMC warning information
The SINAMICS converter systems G130, G150, S120 Chassis units, S120 Cabinet Modules and S150 are not
designed to be connected to public networks (first environment). RFI suppression of these converter systems is
designed for industrial networks (second environment) in accordance with the EMC product standard EN 61800-3 for
variable-speed drives. If the converter systems are connected to public networks (first environment) electromagnetic
interference can occur. With additional measures (e.g. EMC-filters) the converter systems can also be connected to
public networks