Siemens SINAMICS G130 Engineering Manual page 41

Sinamics - low voltage sinamics drives
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

Output
Frame
power
size
SINAMICS
G150
at 400V /
500V / 690V
[ kW ]
[ - ]
SINAMICS G150 / 380 V – 480 V 3AC
110
F
132
F
160
G
200
G
250
G
315
H
400
H
450
H
560
J
630
2 x H
710
2 x H
900
2 x H
SINAMICS G150 / 500 V – 600 V 3AC
110
G
132
G
160
G
200
G
250
H
315
H
400
H
500
J
560
J
630
2 x H
710
2 x H
1000
2 x J
SINAMICS G150 / 660 V – 690 V 3AC
75
F
90
F
110
F
132
F
160
G
200
G
250
G
315
G
400
H
450
H
560
H
710
J
800
J
1000
2 x H
1350
2 x J
1500
2 x J
1750
2 x (GB
JX)
+
1950
2 x (GB
JX)
+
2150
2 x (GB
JX)
+
2400
2 x(GD
JX)
+
2700
2 x(GD
JX)
+
1) These values apply to cabinet units without option L26, i.e. without fuse switch disconnectors including 3NE1 fuses or without circuit breakers
2) These values apply to cabinet units with option L26 = fuse switch disconnectors including 3NE1 fuses
3) These values apply to cabinet units with option L26 = circuit breakers
SINAMICS G150: Maximum and minimum line-side short-circuit currents
Fundamental Principles and System Description
Rated
Maximum
input current
short-circuit current
[ A ]
[ kA ]
1
229
65
/ 65
1
284
65
/ 65
1
338
65
/ 65
1
395
65
/ 50
1
509
65
/ 50
1
629
65
/ 50
1
775
65
/ 50
1
873
84
/ 55
1
1024
84
/ 55
1
1174
2 x 65
/ 2 x 50
1
1444
2 x 65
/ 2 x 50
1624
2 x 55
1
191
65
/ 65
1
224
65
/ 65
1
270
65
/ 65
1
343
65
/ 65
1
426
65
/ 50
1
483
65
/ 50
1
598
65
/ 50
1
764
84
/ 50
1
842
84
/ 84
1
904
2 x 65
/ 2 x 50
1
1116
2 x 65
/ 2 x 50
1
1424
2 x 84
/ 2 x 50
1
93
65
/ 65
1
109
65
/ 65
1
131
65
/ 65
1
164
65
/ 65
1
191
65
/ 65
1
224
65
/ 65
1
270
65
/ 65
1
343
65
/ 65
1
426
65
/ 50
1
483
65
/ 50
1
598
65
/ 50
1
764
84
/ 50
1
842
84
/ 84
1
1116
2 x 65
/ 2 x 50
1
1424
2 x 84
/ 2 x 50
1568
2 x 84
1800
2 x 85
2030
2 x 85
2245
2 x 85
2510
2 x 85
2865
2 x 85
Engineering Information
Minimum
short-circuit
current
[ kA ]
2
3.0
2
3.6
2
4.4
2
4.4
2
8.0
2
10.0
2
10.5
3
1
3
16.0
/ 1,8
3
1
3
18.4
/ 2.0
2
2 x 10.0
2
2 x 10.5
2 x 1.8
2
2.4
2
3.0
2
3.6
2
5.2
2
5.2
2
6.2
2
8.4
2
10.5
3
1
3
10.4
/ 1,8
2
2 x 6.2
2
2 x 8.4
2
2 x 10.5
2
1.1
2
1.1
2
1.2
2
1.6
2
2.4
2
3.0
2
3.6
2
5.2
2
5.2
2
6.2
2
8.4
2
10.5
3
1
3
10.4
/ 2.0
2
2 x 8.4
2
2 x 10.5
2 x 1.8
2 x 1.8
2 x 2.0
2 x 2.3
2 x 2.5
2 x 2.5
SINAMICS Engineering Manual – November 2015
Min. relative
Max. relative
short-circuit
short-circuit
power
voltage
RSC
v
min
k max
[ - ]
[ % ]
13.1
7.6
12.7
7.9
13.0
7.7
11.1
9.0
15.7
6.4
15.9
6.3
13.6
7.4
1
3
1
3
18.3
/ 2.1
5.5
/ ≈ 10
1
3
1
3
18.0
/ 2.0
5.6
/ ≈ 10
17.0
5.9
14.5
6.9
2.1
≈ 10
12.6
8.0
13.4
7.5
13.3
7.5
15.2
6.6
12.2
8.2
12.8
7.8
14.0
7.1
13.7
7.3
1
3
1
3
12.4
/ 2.1
8.1
/ ≈ 10
13.7
7.3
15.1
6.6
14.7
6.8
11.8
8.5
10.1
10.0
9.2
11.0
9.8
10.2
12.6
8.0
13.4
7.5
13.3
7.5
15.2
6.6
12.2
8.2
12.8
7.8
14.0
7.1
13.7
7.3
1
3
1
3
12.4
/ 2.4
8.1
/ ≈ 10
15.1
6.6
14.8
6.8
2.3
≈ 10
2.0
≈ 10
2.0
≈ 10
2.0
≈ 10
2.0
≈ 10
1.8
≈ 10
41/528
Ó Siemens AG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g150Sinamics s120Sinamics s150

Table of Contents