Description of Options
Engineering Information
9.4

Options K90 (CU320-2 DP), K95 (CU320-2 PN) and K94 (Performance expansion)

These options are available for SINAMICS S120 Cabinet Modules. (air-cooled and liquid-cooled units).
To all Line Modules and Motor Modules, i.e.
·
Basic Line Modules,
·
Smart Line Modules,
·
Active Line Modules,
·
Motor Modules of Booksize Cabinet Kits,
·
Motor Modules in Chassis format.
a CU320-2 DP Control Unit (PROFIBUS) can be assigned as option K90, or a CU320-2 PN Control Unit (PROFINET) as
option K95, including the appropriate CompactFlash card, which then performs communication and open-loop / closed-loop
control functions. The CU320-2 DP Control Unit is equipped with a PROFIBUS interface as standard and the CU320-2 PN
Control Unit with a PROFINET interface as standard. The SINAMICS S120 firmware is stored on the CompactFlash card.
Options K90 and K95 consist in each case of the relevant CU320-2 Control Unit and a CompactFlash card without
performance expansion. Either of these CU320-2 Control Units can control a maximum of 3 servo axes or 3 vector
axes or 6 V/f axes. More detailed information can be found in subsection "Determination of the required control
performance of the CU320-2 Control Unit" in section "Control properties" of chapter "General Information about Built-
in and Cabinet Units SINAMICS S120".
The full computing capacity of the CU320-2 Control Unit can be utilized only if firmware option "Performance
expansion" is provided. With this performance expansion, the CU320-2 can control a maximum of 6 servo axes or
6 vector axes or 12 V/f axes. If a CU320-2 Control Unit with performance expansion is required, option K94 must be
ordered in addition to option K90 or K95. A CompactFlash card with performance expansion is shipped with the
CU320-2 DP Control Unit when it is ordered with option combination K90 / K94 and with the CU320-2 PN Control
Unit when it is ordered with option combination K95 / K94.
The performance expansion is supplied in the form of a license which is stored on the CompactFlash card as a
license code at the factory. The performance expansion option can also be enabled retrospectively on site in cases,
for example, where the customer did not realize that this feature would be needed at the time the order was placed.
The serial number of the CompactFlash card and the order number of the firmware option to be enabled are essential
for the purpose of enabling performance expansion retrospectively. With this information, the appropriate license
code can be purchased from a license database and the firmware option then can be enabled. The license code is
valid only for the identified CompactFlash card and cannot be transferred to other cards.
The CompactFlash card supplied with the CU320-2 Control Unit contains the SINAMICS S120 firmware. Firmware
version and performance expansion are encoded in the order number of the CompactFlash card. The order number
can be found on the sticker on the CompactFlash card.
Order No.:
Firmware version 1
2
3
4
.1
.2
.3
.4
.5
.6
.7
.8
Without performance expansion
With performance expansion
Encoding of firmware version and performance expansion in the order num-
ber of the CompactFlash card containing the firmware for SINAMICS S120
Note:
A CompactFlash card with a storage capacity of 1 GB is an essential requirement of the CU320-2 Control Unit (or 2
GB with 4.6 HF3 and higher). Firmware version 4.3 or higher is the minimum requirement for the CU320-2 DP and
firmware version 4.4 or higher for the CU320-2 PN.
Older CompactFlash cards belonging to the CU320 Control Unit with a storage capacity of 64 MB or less, and
firmware version 2.6 or lower, are not compatible with the CU320-2 Control Unit.
SINAMICS Engineering Manual – November 2015
502/528
Ó Siemens AG
6SL3054-0 _ _ 0_-1BA0
B
C
D
E
B
C
D
E
F
G
H
J
0
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g150Sinamics s120Sinamics s150