Siemens SINAMICS G130 Engineering Manual page 347

Sinamics - low voltage sinamics drives
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

SINAMICS S120 Motor Modules
in formats
Chassis and Cabinet Modules
(w/o Booksize Cabinet Kits)
on one CU320-2 Control Unit
Frame sizes FX and GX
510 - 720 V DC / 380 - 480 V 3AC
1 V/f axis
2 V/f axes
3 V/f axes
4 V/f axes
5 V/f axes
6 V/f axes
7 V/f axes
8 V/f axes
9 V/f axes
10 V/f axes
11 V/f axes
12 V/f axes
SINAMICS S120 Motor Modules
in formats
Chassis and Cabinet Modules
(w/o Booksize Cabinet Kits)
on one CU320-2 Control Unit
Frame sizes HX and JX
510 - 720 V DC / 380 - 480 V 3AC
Frame sizes FX, GX, HX and JX
675 - 1035 V DC; 500 - 690 V 3AC
1 vector axis
2 vector axes
3 vector axes
4 vector axes
5 vector axes
6 vector axes
1 V/f axis
2 V/f axes
3 V/f axes
4 V/f axes
5 V/f axes
6 V/f axes
7 V/f axes
8 V/f axes
9 V/f axes
10 V/f axes
11 V/f axes
12 V/f axes
SINAMICS S120 Motor Modules in Chassis and Cabinet Modules formats on one CU320-2 Control Unit with firmware 4.3:
Interdependencies the between number of axes, associated current controller cycle and settable pulse frequencies
For maximum possible output frequencies and the current derating factors applicable at increased pulse frequencies,
please refer to section "Rated data, permissible output currents, maximum output frequencies". Further information
can be found also in the function manual "SINAMICS S120 Drive Functions".
With firmware version 4.4, a minimum current controller clock cycle of 125 μs can be set in vector-type drive objects
with SINAMICS S units in Chassis and Cabinet Modules formats. The only exception are the SINAMICS S parallel
converters for which a minimum current controller clock cycle of 200 μs can be set.
The maximum possible output frequency is thus 550 Hz in the standard firmware. When the license "High output
frequency" for SINAMICS S is purchased, the maximum possible output frequency is 650 Hz for units with f
8.0 kHz and a current controller clock cycle of 125 μs, and 623 Hz for units with f
latter case f
must be set to 7.477 kHz and the current controller clock cycle to 133.75 μs.
Pulse
The maximum possible number of axes which can be connected to a CU320-2 is therefore generally limited to one.
Current
Pulse frequency
controller
clock cycle
Standard
(w/o current
derating)
µs
kHz
250
2
250
2
250
2
250
2
250
2
250
2
400
1.25
400
1.25
400
1.25
500
1.00
500
1.00
500
1.00
Current
Pulse frequency
controller
clock cycle
Standard
(w/o current
derating)
µs
kHz
400
1.25
400
1.25
400
1.25
400
1.25
500
1.00
500
1.00
400
1.25
400
1.25
400
1.25
400
1.25
400
1.25
400
1.25
400
1.25
400
1.25
400
1.25
500
1.00
500
1.00
500
1.00
SINAMICS Engineering Manual – November 2015
Engineering Information
With current derating
(for current derating factors, see section
"Rated data, permissible output currents,
maximum output frequencies")
kHz
kHz
4
8
4
8
4
8
4
8
4
8
4
8
2.5
5
2.5
5
2.5
5
2
4
2
4
2
4
With current derating
(for current derating factors, see section
"Rated data, permissible output currents,
maximum output frequencies")
kHz
kHz
2.5
5
2.5
5
2.5
5
2.5
5
2
4
2
4
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5
2
4
2
4
2
4
Pulse max
Ó Siemens AG
SINAMICS S120
Performance
expansion
required
kHz
-
No
-
No
-
No
-
No
-
No
-
No
7.5
Yes
7.5
Yes
7.5
Yes
6
Yes
6
Yes
6
Yes
Performance
expansion
required
kHz
7.5
No
7.5
No
7.5
No
7.5
Yes
6
Yes
6
Yes
7.5
No
7.5
No
7.5
No
7.5
No
7.5
No
7.5
No
7.5
Yes
7.5
Yes
7.5
Yes
6
Yes
6
Yes
6
Yes
=
Pulse max
= 7.5 kHz, where in the
347/528

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g150Sinamics s120Sinamics s150

Table of Contents